- Description
- A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The SFTP service (default port 22/tcp) of the Control Center Server (CCS) contains an authentication bypass vulnerability. A remote attacker with network access to the CCS server could exploit this vulnerability to read data from the EDIR directory (for example, the list of all configured stations).
- Source
- productcert@siemens.com
- NVD status
- Modified
CVSS 3.1
- Type
- Primary
- Base score
- 5.3
- Impact score
- 1.4
- Exploitability score
- 3.9
- Vector string
- CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N
- Severity
- MEDIUM
CVSS 2.0
- Type
- Primary
- Base score
- 5
- Impact score
- 2.9
- Exploitability score
- 10
- Vector string
- AV:N/AC:L/Au:N/C:P/I:N/A:N
- Hype score
- Not currently trending
[
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:sinvr_3_central_control_server:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "16668E9A-2D0A-425E-87F4-18CFC50551D3"
},
{
"criteria": "cpe:2.3:a:siemens:sinvr_3_video_server:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "0F21BB6D-BFE0-4B69-97F2-1A871A390B1E"
}
],
"operator": "OR"
}
]
}
]