- Description
- An issue exists in SoftIron HyperCloud where drive caddy removal and reinsertion without a reboot may erroneously cause the system to recognize the caddy as new media and wipe all data on the drives due to a missing synchronization flaw, which impacts data availability and integrity. This issue only impacts SoftIron HyperCloud "density" storage nodes running HyperCloud software versions 1.0 to before 2.0.3.
- Source
- 0a72a055-908d-47f5-a16a-1f09049c16c6
- NVD status
- Modified
CVSS 3.1
- Type
- Primary
- Base score
- 6.1
- Impact score
- 5.2
- Exploitability score
- 0.9
- Vector string
- CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H
- Severity
- MEDIUM
- Hype score
- Not currently trending
[
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:softiron:hypercloud:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "1E1D94F5-3EE0-4D00-BF00-C08BB922F813",
"versionEndExcluding": "2.0.3",
"versionStartIncluding": "1.0"
}
],
"operator": "OR"
}
]
}
]