- Description
- A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateGateways' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25915)
- Source
- productcert@siemens.com
- NVD status
- Awaiting Analysis
CVSS 4.0
- Type
- Secondary
- Base score
- 8.7
- Impact score
- -
- Exploitability score
- -
- Vector string
- CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Severity
- HIGH
CVSS 3.1
- Type
- Primary
- Base score
- 8.8
- Impact score
- 5.9
- Exploitability score
- 2.8
- Vector string
- CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
- Severity
- HIGH
- productcert@siemens.com
- CWE-89
- Hype score
- Not currently trending
🚨 CVE-2025-31352 🔴 HIGH (8.8) 🏢 Siemens - TeleControl Server Basic 🏗️ 0 🔗 https://t.co/Jd9H3wF1sP #CyberCron #VulnAlert #InfoSec https://t.co/rKmy1EGAaV
@cybercronai
17 Apr 2025
16 Impressions
0 Retweets
0 Likes
0 Bookmarks
0 Replies
0 Quotes
CVE-2025-31352 A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the interna… https://t.co/D2TdmvOVe4
@CVEnew
16 Apr 2025
116 Impressions
0 Retweets
0 Likes
0 Bookmarks
0 Replies
0 Quotes