- Description
- CWE-415: Double Free vulnerability exists that could cause heap memory corruption when the end user imports a malicious project file (SSD file) shared by the attacker into Rapsody.
- Source
- cybersecurity@se.com
- NVD status
- Analyzed
- Products
- ecostruxure_power_build_-_rapsody
CVSS 4.0
- Type
- Secondary
- Base score
- 8.4
- Impact score
- -
- Exploitability score
- -
- Vector string
- CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:L/SI:L/SA:L/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Severity
- HIGH
CVSS 3.1
- Type
- Primary
- Base score
- 5.3
- Impact score
- 3.4
- Exploitability score
- 1.8
- Vector string
- CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:L
- Severity
- MEDIUM
- cybersecurity@se.com
- CWE-415
- Hype score
- Not currently trending
CVE-2025-13844 CWE-415: Double Free vulnerability exists that could cause heap memory corruption when the end user imports a malicious project file (SSD file) shared by the attacker… https://t.co/JJRiEHS3cK
@CVEnew
15 Jan 2026
85 Impressions
0 Retweets
0 Likes
0 Bookmarks
0 Replies
0 Quotes
We have just added an important vulnerability affecting Schneider Electric EcoStruxure Power Build Rapsody (CVE-2025-13844) https://t.co/5u5qSMwI6z
@vuldb
15 Jan 2026
7 Impressions
0 Retweets
0 Likes
0 Bookmarks
0 Replies
0 Quotes
[
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:schneider-electric:ecostruxure_power_build_-_rapsody:*:*:*:*:fr:*:*:*",
"matchCriteriaId": "B0F9F08A-DA7C-404C-B846-0439C1BB68C0",
"versionEndIncluding": "2.8.1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:schneider-electric:ecostruxure_power_build_-_rapsody:*:*:*:*:bel_nl:*:*:*",
"matchCriteriaId": "35A14DC6-6CAE-4ABA-812E-D60A5A556284",
"versionEndIncluding": "2.8.3",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:schneider-electric:ecostruxure_power_build_-_rapsody:*:*:*:*:es:*:*:*",
"matchCriteriaId": "776BC34F-121F-4FE8-BE20-0A46433225AA",
"versionEndIncluding": "2.8.5",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:schneider-electric:ecostruxure_power_build_-_rapsody:*:*:*:*:int:*:*:*",
"matchCriteriaId": "20D6437D-D54C-407D-A301-0F11AF975235",
"versionEndIncluding": "2.8.6",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:schneider-electric:ecostruxure_power_build_-_rapsody:*:*:*:*:bel_fr:*:*:*",
"matchCriteriaId": "2C0E74D9-8163-45EA-89C3-F103CFFDF427",
"versionEndIncluding": "2.8.8",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
]