- Description
- A vulnerability has been identified in Solid Edge SE2024 (All versions < V224.0 Update 14), Solid Edge SE2025 (All versions < V225.0 Update 6). The affected applications contains an out of bounds write vulnerability while parsing specially crafted PRT files. This could allow an attacker to crash the application or execute code in the context of the current process.
- Source
- productcert@siemens.com
- NVD status
- Analyzed
- Products
- solid_edge_se2024, solid_edge_se2025
CVSS 4.0
- Type
- Secondary
- Base score
- 7.3
- Impact score
- -
- Exploitability score
- -
- Vector string
- CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Severity
- HIGH
CVSS 3.1
- Type
- Primary
- Base score
- 7.8
- Impact score
- 5.9
- Exploitability score
- 1.8
- Vector string
- CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
- Severity
- HIGH
- productcert@siemens.com
- CWE-787
- Hype score
- Not currently trending
**CVE-2025-40810** is a high-severity vulnerability affecting **Solid Edge** versions prior to specific updates. It involves an **out-of-bounds write** flaw within the application's parsing logic for **specially crafted PRT (Part) files**. This flaw can lead to **application
@CveTodo
14 Oct 2025
38 Impressions
0 Retweets
0 Likes
0 Bookmarks
0 Replies
0 Quotes
CVE-2025-40810 A vulnerability has been identified in Solid Edge SE2024 (All versions < V224.0 Update 14), Solid Edge SE2025 (All versions < V225.0 Update 6). The affected applicati… https://t.co/dfTiEbcHE1
@CVEnew
14 Oct 2025
88 Impressions
0 Retweets
1 Like
0 Bookmarks
0 Replies
0 Quotes
[
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:-:*:*:*:*:*:*:*",
"matchCriteriaId": "893736B3-0140-4775-8700-CB9D7719DDE5",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:-:*:*:*:*:*:*",
"matchCriteriaId": "A0119E8F-1FAF-4A3B-B6E9-20F78360FC82",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0001:*:*:*:*:*:*",
"matchCriteriaId": "829C4AEB-7C8D-408B-A79C-8684753F45E1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_00010:*:*:*:*:*:*",
"matchCriteriaId": "8E262AB3-8C47-430A-9D42-89317CB630C5",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_00011:*:*:*:*:*:*",
"matchCriteriaId": "94758C94-F427-480E-A9F1-109D8660C4E0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_00012:*:*:*:*:*:*",
"matchCriteriaId": "D084D11C-08FB-4EEE-A5E3-D93C10103D2A",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_00013:*:*:*:*:*:*",
"matchCriteriaId": "F8A834C5-1E45-4087-A3A4-C059A2C9960C",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0002:*:*:*:*:*:*",
"matchCriteriaId": "1E8FB23E-280D-46FD-BD44-5D4552639E00",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0003:*:*:*:*:*:*",
"matchCriteriaId": "CA2417A0-DD31-46FC-8D5A-9128B86C9352",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0004:*:*:*:*:*:*",
"matchCriteriaId": "3CA9C494-767C-4CFA-AB07-106298B7B2C4",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0005:*:*:*:*:*:*",
"matchCriteriaId": "C3738D73-82A5-41E4-8083-34611A6301BE",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0006:*:*:*:*:*:*",
"matchCriteriaId": "5634352F-0DD1-4731-9E43-61D0A9A40D1B",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0007:*:*:*:*:*:*",
"matchCriteriaId": "32E3D549-54F0-4909-830D-BDE8CDAD5AF7",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0008:*:*:*:*:*:*",
"matchCriteriaId": "1137D7B3-17AD-4997-AC19-4308AA5C9438",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0009:*:*:*:*:*:*",
"matchCriteriaId": "E5488DEB-3165-4F88-8C63-7B9BC212DEFF",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2025:-:*:*:*:*:*:*:*",
"matchCriteriaId": "9EBC379B-A9D5-4587-87A1-59D2D8EF2267",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2025:225.0:-:*:*:*:*:*:*",
"matchCriteriaId": "3D717792-2F86-43CD-973B-249171094C6C",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2025:225.0:update_0001:*:*:*:*:*:*",
"matchCriteriaId": "2C6F3C20-8AB5-4A6A-8524-C7CBC4A4D973",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2025:225.0:update_0002:*:*:*:*:*:*",
"matchCriteriaId": "03CCA3A8-F8D6-4C80-BC03-15B865CE46B7",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2025:225.0:update_0003:*:*:*:*:*:*",
"matchCriteriaId": "B51556E8-9A3B-4755-BC2C-8FACABC01A7B",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2025:225.0:update_0004:*:*:*:*:*:*",
"matchCriteriaId": "737A4807-387D-4099-880D-2CCEE7B77B44",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2025:225.0:update_0005:*:*:*:*:*:*",
"matchCriteriaId": "9267F09C-5EFD-443F-ABE0-974C1D034464",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
]