CVE-2025-5023

Published Jul 10, 2025

Last updated a day ago

Overview

Description
Use of Hard-coded Credentials vulnerability in Mitsubishi Electric Corporation photovoltaic system monitor “EcoGuideTAB” PV-DR004J all versions and PV-DR004JA all versions allows an attacker within the Wi-Fi communication range between the units of the product (measurement unit and display unit) to disclose information such as generated power and electricity sold back to the grid stored in the product, tamper with or destroy stored or configured information in the product, or cause a Denial-of-Service (DoS) condition on the product, by using hardcoded user ID and password common to the product series obtained by exploiting CVE-2025-5022. However, the product is not affected by this vulnerability when it remains unused for a certain period of time (default: 5 minutes) and enters the power-saving mode with the display unit's LCD screen turned off. The affected products discontinued in 2015, support ended in 2020.
Source
Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp
NVD status
Awaiting Analysis
CNA Tags
unsupported-when-assigned

Risk scores

CVSS 3.1

Type
Secondary
Base score
7.1
Impact score
5.5
Exploitability score
1.6
Vector string
CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:L/I:H/A:H
Severity
HIGH

Weaknesses

Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp
CWE-798

Social media

Hype score
Not currently trending

References

Sources include official advisories and independent security research.