- Description
- Use of Hard-coded Credentials vulnerability in Mitsubishi Electric Corporation photovoltaic system monitor “EcoGuideTAB” PV-DR004J all versions and PV-DR004JA all versions allows an attacker within the Wi-Fi communication range between the units of the product (measurement unit and display unit) to disclose information such as generated power and electricity sold back to the grid stored in the product, tamper with or destroy stored or configured information in the product, or cause a Denial-of-Service (DoS) condition on the product, by using hardcoded user ID and password common to the product series obtained by exploiting CVE-2025-5022. However, the product is not affected by this vulnerability when it remains unused for a certain period of time (default: 5 minutes) and enters the power-saving mode with the display unit's LCD screen turned off. The affected products discontinued in 2015, support ended in 2020.
- Source
- Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp
- NVD status
- Awaiting Analysis
- CNA Tags
- unsupported-when-assigned
CVSS 3.1
- Type
- Secondary
- Base score
- 7.1
- Impact score
- 5.5
- Exploitability score
- 1.6
- Vector string
- CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:L/I:H/A:H
- Severity
- HIGH
- Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp
- CWE-798
- Hype score
- Not currently trending
CVE-2025-5023 (CVSS:7.1, HIGH) is Awaiting Analysis. Use of Hard-coded Credentials vulnerability in Mitsubishi Electric Corporation photovoltaic system monitor “EcoGuideTAB”..https://t.co/NpxjiGg3xS #cybersecurityawareness #cybersecurity #CVE #infosec #hacker #nvd #mitre
@cracbot
15 Jul 2025
6 Impressions
0 Retweets
0 Likes
0 Bookmarks
0 Replies
0 Quotes
CVE-2025-5023 Hard-Coded Credentials Vulnerability in Mitsubishi EcoGuideTAB Photovoltaic Monitor https://t.co/KQ4b9RhczR
@VulmonFeeds
10 Jul 2025
12 Impressions
0 Retweets
0 Likes
0 Bookmarks
0 Replies
0 Quotes