CVE-2026-111497
Published Oct 22, 2026
Last updated 5 days ago
AI description
CVE-2026-111497 is a vulnerability affecting the Brotli decompression library integrated into Node.js (specifically within the 22.x, 24.x, and 26.x release lines) and other platforms like Envoy. The flaw is characterized as an out-of-bounds write memory error in the Brotli decoder. When a system decodes Brotli-compressed data, a bug in how the decoder unpacks the data allows it to write past the end of its allocated memory block. This memory corruption can be triggered when an application processes untrusted or malicious Brotli-compressed content, potentially allowing an attacker to leak memory or achieve remote code execution (RCE). To mitigate this issue, users are advised to update to patched versions of Node.js, which include 22.23.4, 24.22.1, and 26.12.1.
- Description
- A buffer overflow vulnerability in the Brotli decoder (c/dec/decode.c) in Google Brotli versions 1.0.3 through 1.2.0 on all platforms allows a remote unauthenticated attacker to corrupt adjacent decoder state memory, disclose sensitive memory contents, cause a denial of service, or potentially execute arbitrary code using a crafted Brotli-compressed stream. Users need to update any Brotli libraries or binaries between 1.0.3 through 1.2.0 to the latest available version: 1.0.10 or 1.1.1 or 1.2.1.
- Source
- cve-coordination@google.com
- NVD status
- Analyzed
- Products
- brotli, node.js, brotlicffi, .net, debian_linux, istio, bun, envoy, edk2, woff2, duckdb, clickhouse, arrow, 7-zip-zstd, p7zip, brotli, ruggedcom_ape1808_firmware, common_configurator, data_flow_monitoring, dataxess_configurator, edge_opc_ua_server_configurator, flow_creator_configurator, industrial_edge_cloud_connector_configurator, industrial_edge_databus_configurator, industrial_edge_hub, industrial_edge_management_cloud, comos_walkinside, simatic_braumat, simatic_profiling_tool, simatic_sistar, simatic_wincc, simatic_wincc_companion, simatic_wincc_runtime, simatic_wincc_unified_for_industrial_edge, simatic_wincc_unified_pc_runtime, simatic_wincc_unified_siqence, tia_administrator, tia_project-server_web_administration_tool, user_management_component, hyperlynx, innexis_architecture_native_acceleration, insights_hub, opcenter_connect_electronics, opcenter_connect_manufacturing_operations_management, opcenter_execution_core, opcenter_execution_discrete, opcenter_execution_foundation, opcenter_execution_pharma, opcenter_execution_process, opcenter_intelligence, opcenter_quality, opcenter_rd\&l, opcenter_x, pads_professional, pave360_automotive, process_preparation_x, simcenter_executable_digital_twin, simcenter_studio, teamcenter, xpedition_designer, xpedition_enterprise
CVSS 4.0
- Type
- Secondary
- Base score
- 9.2
- Impact score
- -
- Exploitability score
- -
- Vector string
- CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Severity
- CRITICAL
CVSS 3.1
- Type
- Primary
- Base score
- 9.8
- Impact score
- 5.9
- Exploitability score
- 3.9
- Vector string
- CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
- Severity
- CRITICAL
Data from CISA
- Vulnerability name
- Google Brotli Unchecked Return Value Vulnerability
- Exploit added on
- Oct 27, 2026
- Exploit action due
- Nov 10, 2026
- Required action
- Apply mitigations in accordance with vendor instructions, ensuring compliance with CISA’s BOD 26-04 Prioritizing Security Updates Based on Risk (see URL in Notes) guidance and CISA’s “Forensics Triage Requirements” (see URL in Notes). Follow applicable BOD 26-04 guidance for cloud services or discontinue use of the product if mitigations are unavailable. Stakeholders are responsible for evaluating each asset's internet exposure and ensuring adherence to BOD 26-04 patching guidelines.
- cve-coordination@google.com
- CWE-252
- Hype score
- Not currently trending
CRITICAL: CVE-2026-119618 — unauthenticated RCE in Apache mod_http2 Affects 2.4.55–2.4.70 with HTTP/2 on. Fixed in 2.4.71 (Nov 11). Interim: disable h2. Node2Shell CVE-2026-111497 exploited in the wild. #ThreatIntel #CVE #CVE2026119618
@NoctisIntel
15 Nov 2026
2 Impressions
0 Retweets
0 Likes
0 Bookmarks
0 Replies
0 Quotes
NØØT KEV Shift Classification: Critical CVE: CVE-2026-111497 Product: Google — Brotli Summary: CISA confirms active exploitation of CVE-2026-111497 through its KEV catalog. Affected products include: Google — Brotli. Evidence: Active exploitation confirmed by CISA KEV;
@Python_s_
12 Nov 2026
71 Impressions
0 Retweets
0 Likes
0 Bookmarks
0 Replies
0 Quotes
Researchers observed attackers silently joining iMessage group chats via CVE-2026-113961 — no user interaction, no visible presence, and immediate access to historical messages via CVE-2026-113960. Combined with a Brotli decoder flaw (CVE-2026-111497) already on CISA KEV, the
@aviatrixtrc
10 Nov 2026
54 Impressions
0 Retweets
0 Likes
0 Bookmarks
0 Replies
0 Quotes
2Shell jokes have a real bug behind them: CVE-2026-111497, OOB write in the Brotli decoder. CVSS 9.2, exploited in the wild, bundled in Node, Bun, Python, .NET, Envoy. CISA KEV deadline is tomorrow, Nov 10. fix: Brotli 1.2.1. #Node2Shell #CVE #InfoSec #CyberSecurity
@ksanjeev284
9 Nov 2026
83 Impressions
0 Retweets
0 Likes
0 Bookmarks
0 Replies
0 Quotes
i made NEXT3SH v9 a fully weaponised automated zero click exploit covering all CVE-2026-109618 -PHP2Shell CVE-2026-111497 -the Brotli/Node2Shell CVE-2026-75604 - React2Shell2 CVE-2026-96889 -NEXT2SHELLnext2 CVE-2026-94483 - brotli bomb check insta 4 more https://t.co/XS8JhCeHW7
@getohacks
9 Nov 2026
5 Impressions
0 Retweets
0 Likes
0 Bookmarks
0 Replies
0 Quotes
How to check and fix the Node.js Brotli decoder flaw (CVE-2026-111497) in the process that serves traffic CVE-2026-111497 is an out-of-bounds write in the Brotli decoder bundled with Node.js 22.x, 24.x and 26.x. Malformed Brotli data… https://t.co/w73UgP6OMC #SystemDesign ht
@SysDesignSimple
8 Nov 2026
66 Impressions
0 Retweets
0 Likes
0 Bookmarks
0 Replies
0 Quotes
NEXTSH v9 a fully weaponised automated zero click exploit covering all CVE-2026-109618 CVE-2026-111497CVE-2026-75604 CVE-2026-96889 CVE-2026-94483 it can take down an entire nations for poc of live exploitation visit Instagram https://t.co/cfZVAl1btY https://t.co/9mQKbmnxYn
@getohacks
7 Nov 2026
26 Impressions
0 Retweets
0 Likes
0 Bookmarks
1 Reply
0 Quotes
ZDW BRIEF: KEV deadlines coming up Nov 10: Adobe Commerce/Magento CVE-2026-48356 and Google Brotli CVE-2026-111497 Nov 11: VMware ESX CVE-2026-41709 Nov 13: Ivanti Connect Secure CVE-2026-118527 All are on CISA's exploited list. Run any of them? Patch before the date.
@0daywatch
7 Nov 2026
0 Impressions
0 Retweets
0 Likes
0 Bookmarks
0 Replies
0 Quotes
PHP2Shell (CVE-2026-109618/109619) and Node2Shell (CVE-2026-111497) are on CISA KEV. These runtime bugs are invisible to code review. Patch PHP and Node.js, rebuild container images, restart services. #php #nodejs #infosec https://t.co/ksgCcmm1C3 https://t.co/W4lNgMu9cS
@4tifysecurity
7 Nov 2026
29 Impressions
0 Retweets
0 Likes
0 Bookmarks
2 Replies
0 Quotes
KEV of the week (W44): PHP "php2shell" (CVE-2026-109618, CVE-2026-109619), GitLab CE/EE (CVE-2026-97229) and Brotli (CVE-2026-111497) were added to CISA's exploited list. Patch PHP, GitLab, brotli 1.2.1. Priosweep ranks what matters first. Which one is in your stack? https://t.co
@Priosweep
3 Nov 2026
9 Impressions
0 Retweets
0 Likes
0 Bookmarks
1 Reply
0 Quotes
Arista fixed critical Arista security vulnerabilities CVE-2026-111497 and CVE-2026-98432 that allow unauthenticated remote code execution. Update now. #Arista #VeloCloud #LinuxKernel #RCE #CVE2026111497 #CVE202698432 #Cybersecurity #InfoSec https://t.co/H4wvOUUTMt
@Daily_CyberSec
3 Nov 2026
286 Impressions
0 Retweets
0 Likes
0 Bookmarks
0 Replies
0 Quotes
Patch now: Microsoft warns PHP2Shell (CVE-2026-109618, CVE-2026-109619) and a Brotli flaw (CVE-2026-111497) are actively exploited. Update PHP, .NET, Node.js, PowerShell 7 and Visual Studio, and don't skip the extra restart. QFD can help. https://t.co/9KYRScrdWj #CyberSecurity
@QFDNews
2 Nov 2026
108 Impressions
0 Retweets
0 Likes
0 Bookmarks
0 Replies
0 Quotes
Worst CVEs of last week (2026-W44), ranked by the https://t.co/FMjwIcXfuO Index: 1. CVE-2026-97229 GitLab (95) 2. CVE-2026-111497 Google Brotli · node +6 (92) 3. CVE-2026-109618 PHP Group PHP (92) 4. CVE-2026-109619 PHP Group PHP (92) https://t.co/SlSk2DUrYZ
@cvedotnow
2 Nov 2026
9365 Impressions
16 Retweets
78 Likes
22 Bookmarks
0 Replies
1 Quote
VMSA-2026-0008: Critical SDDC Manager RCE — CVE-2026-111497 | Critical SDDC Manager RCE (CVE-2026-111497): affected VCF versions, CVSS 9.8 vs. 7.5, and Broadcom's manual workarounds while patches are pending. – #vExpert Christopher Kusak https://t.co/fEyDrzyA9V https://t.co/C
@PhotoZel
2 Nov 2026
39 Impressions
0 Retweets
0 Likes
0 Bookmarks
0 Replies
0 Quotes
【セキュリティに関するお知らせ】 Node.jsの脆弱性(CVE-2026-111497、CVE-2026-105482、CVE-2026-105483、CVE-2026-106069)について、Zoho製品への影響はございません。 詳細は以下をご確認ください。 https://t.co/YvXydSPCAK
@jpzohosupport
2 Nov 2026
60 Impressions
0 Retweets
0 Likes
0 Bookmarks
0 Replies
0 Quotes
Brotli CVE-2026-111497 Is Being Exploited, and It's Not Just Node.js #brotli #cve #devops #sre This is a clip from our recent Ship It Weekly Podcast episode. Visit link in bio to listen to the full episode! https://t.co/mtF8E7l0ru
@TellersTech
1 Nov 2026
10 Impressions
0 Retweets
0 Likes
0 Bookmarks
0 Replies
0 Quotes
VMSA-2026-0008: Critical SDDC Manager RCE — CVE-2026-111497 | Critical SDDC Manager RCE (CVE-2026-111497): affected VCF versions, CVSS 9.8 vs. 7.5, and Broadcom's manual workarounds while patches are pending. – #vExpert Christopher Kusak https://t.co/xavmzsBqr2 https://t.co/n
@vcdx001
1 Nov 2026
127 Impressions
0 Retweets
0 Likes
0 Bookmarks
0 Replies
0 Quotes
Node.js RCE Exploit: CVE-2026-111497 🔥 XHack AI took CVE-2026-111497 apart. 🔬 No copied PoCs. No assumptions. We rebuilt the exploit in an isolated lab and confirmed Remote Code Execution (RCE) on an unmodified Node.js build. Here's what we discovered. 🧵 #NodeJS htt
@salmanite
1 Nov 2026
135 Impressions
1 Retweet
2 Likes
0 Bookmarks
2 Replies
0 Quotes
CVE-2026-115946: fallo de memoria en XS::libbrotli. La librería compila su propio brotli estático (1.0.7/1.1.0) que arrastra el bug CVE-2026-111497. No hay interfaz directa en Perl, pero cualquier módulo que lo use para descomprimir es vulnerable. #Perl #DevSecOps https://t.
@esteban4dev
1 Nov 2026
61 Impressions
0 Retweets
0 Likes
0 Bookmarks
1 Reply
0 Quotes
Paloaltoの脆弱性情報 「CVE-2026-111497 Portfolio Status: Impact of Brotli Vulnerability (CVE-2026-111497) on Palo Alto Networks Products (Severity: CRITICAL)」が公開されました。 → https://t.co/Gr0IhCllUL
@ripjyr
31 Oct 2026
529 Impressions
0 Retweets
1 Like
1 Bookmark
0 Replies
0 Quotes
VMSA-2026-0008: Critical SDDC Manager RCE — CVE-2026-111497 | Critical SDDC Manager RCE (CVE-2026-111497): affected VCF versions, CVSS 9.8 vs. 7.5, and Broadcom's manual workarounds while patches are pending. – #vExpert Christopher Kusak https://t.co/c2OIYiOKMT https://t.co/T
@SirajD_Official
31 Oct 2026
45 Impressions
0 Retweets
0 Likes
0 Bookmarks
0 Replies
0 Quotes
VMSA-2026-0008: Critical SDDC Manager RCE — CVE-2026-111497 | Critical SDDC Manager RCE (CVE-2026-111497): affected VCF versions, CVSS 9.8 vs. 7.5, and Broadcom's manual workarounds while patches are pending. – #vExpert Christopher Kusak https://t.co/q5Kz1hXYSv https://t.co/Q
@dsimelka
30 Oct 2026
70 Impressions
0 Retweets
0 Likes
0 Bookmarks
0 Replies
0 Quotes
New critical flaws: PHP RCEs (CVE-2026-109618/19), Node.js TLS/Brotli issues (CVE-2026-111497), & a DNS-over-QUIC bug (CVE-2026-97206) threaten data privacy & integrity in transit. Patch now! #Cybersecurity #Anonymous #News
@YourAnon_irc
30 Oct 2026
75 Impressions
0 Retweets
0 Likes
0 Bookmarks
0 Replies
0 Quotes
⚠️ Daily CVE Roundup - October 30, 2026 Here are the notable CVEs disclosed or updated today: 🔴 Critical & High Severity · CVE-2026-111497 (Google Brotli / "Broccoli2Shell") - Critical. An out-of-bounds write in the Brotli decoder allows unauthenticated remote att
@yogsec
30 Oct 2026
238 Impressions
0 Retweets
1 Like
0 Bookmarks
1 Reply
0 Quotes
VMSA-2026-0008: Critical SDDC Manager RCE — CVE-2026-111497 | Critical SDDC Manager RCE (CVE-2026-111497): affected VCF versions, CVSS 9.8 vs. 7.5, and Broadcom's manual workarounds while patches are pending. – #vExpert Christopher Kusak https://t.co/Ao8mQXP0ku https://t.co/z
@kevinpollock
29 Oct 2026
46 Impressions
0 Retweets
0 Likes
0 Bookmarks
0 Replies
0 Quotes
VMSA-2026-0008: Critical SDDC Manager RCE — CVE-2026-111497 | Critical SDDC Manager RCE (CVE-2026-111497): affected VCF versions, CVSS 9.8 vs. 7.5, and Broadcom's manual workarounds while patches are pending. – #vExpert Christopher Kusak https://t.co/zaq5vkOtsx https://t.co/Q
@PhotoZel
29 Oct 2026
33 Impressions
0 Retweets
0 Likes
0 Bookmarks
0 Replies
0 Quotes
🔒 #CyberSecurity CVE-2026-111497: Adobe Commerce & Magento PolyShell Web Shell Attacks — Detecti… "On Tuesday, CISA added CVE-2026-111497 (CVSS 9.2) — an unchecked return value…" 🔗 https://t.co/GxD6wzBV0o #CyberSecurity #ThreatIntel #cve #zeroday #patchtuesd
@SecurityAr58409
29 Oct 2026
43 Impressions
0 Retweets
0 Likes
0 Bookmarks
0 Replies
0 Quotes
Almost every app unpacks data silently. A flaw called Broccoli2Shell, Node2Shell, or HTTP2Shell (CVE-2026-111497) needs no password to exploit. Swipe through >>> #CyberSecurity #CVE #CloudSecurity https://t.co/EIJj8tfrIQ
@GT_consult
29 Oct 2026
52 Impressions
0 Retweets
0 Likes
0 Bookmarks
0 Replies
0 Quotes
⚠️ Daily CVE Roundup - October 29, 2026 Here are the notable CVEs disclosed or updated today: 🔴 Critical & High Severity · CVE-2026-111497 (Google Brotli / Node.js "Node2Shell") - CVSS 9.2 (Critical) Out-of-bounds write in the Brotli decoder allows unauthenticated
@yogsec
29 Oct 2026
200 Impressions
0 Retweets
1 Like
0 Bookmarks
0 Replies
0 Quotes
Paloaltoの脆弱性情報 「CVE-2026-111497 Portfolio Status: Impact of Brotli Vulnerability (CVE-2026-111497) on Palo Alto Networks Products (Severity: CRITICAL)」が公開されました。 → https://t.co/Gr0IhCllUL
@ripjyr
29 Oct 2026
84 Impressions
0 Retweets
0 Likes
0 Bookmarks
0 Replies
0 Quotes
CVE-2026-111497 — Google Brotli Unchecked Return Value Vulnerability https://t.co/osIxOngFAX
@Npj8448
29 Oct 2026
74 Impressions
0 Retweets
0 Likes
0 Bookmarks
0 Replies
0 Quotes
Brotli2Shell: Frequently asked questions for Google Brotli decoder vulnerability (CVE-2026-111497) According to Tenable, a vulnerability in Google's Brotli decoder library, identified as CVE-2026-111497, has been… https://t.co/MSepIJSI8P https://t.co/yJLHWxOMPn
@pentestlabwiki
29 Oct 2026
6 Impressions
0 Retweets
0 Likes
0 Bookmarks
0 Replies
0 Quotes
Python packages are also vulnerable to the Node2Shell Brotli flaw (CVE-2026-111497) www.aikido.dev/blog/python-packages-vulnerable-node2shell-brotli-cve-2026-111497 https://t.co/QQIZ57yiX1
@Komodosec
28 Oct 2026
75 Impressions
0 Retweets
0 Likes
0 Bookmarks
0 Replies
0 Quotes
Node2Shell CVE-2026-111497 now on CISA KEV CISA added CVE-2026-111497 (Node2Shell) to KEV on Oct 27 with a Nov 10 federal deadline, per BleepingComputer. Fixed in Node.js 22.23.4, 24.22.1 and 26.12.1; Node 20, 23 and 25 need a version move. Who signs the risk acceptance for Node
@modularciso
28 Oct 2026
14 Impressions
0 Retweets
2 Likes
0 Bookmarks
0 Replies
0 Quotes
🚨 UPDATE: CISA ADDS ADOBE COMMERCE "POLYSHELL" AND GOOGLE BROTLI FLAWS TO KEV (CVE-2026-48356 / CVE-2026-111497) CISA added two vulnerabilities to its Known Exploited Vulnerabilities catalog on Oct 27, 2026. Federal due date for both is Nov 10. What's new: • CVE-2026-48356
@DailyDarkWeb
28 Oct 2026
5168 Impressions
0 Retweets
9 Likes
2 Bookmarks
2 Replies
0 Quotes
Latest News: VulnTX top 4 for Texas, all exploited: 1. Google Brotli · CVE-2026-111497 · 86 · 2 sources ✔ 2. Arista VeloCloud Orchestrator · CVE-2026-114625 · 86 · 2 sources ✔ 3-4. PHP use-after-free pair · CVE-2026-109619 / 109618 · 85 Fixes: https://t.co/E2AJto0vAx
@Aegisrecon
28 Oct 2026
16 Impressions
0 Retweets
0 Likes
0 Bookmarks
0 Replies
0 Quotes
Brotli flaw "HTTP2Shell" (CVE-2026-111497) triggers emergency patches, then lands on CISA's KEV list as exploit traffic appears — CVE-2026-111497 (CVSS 9. #CyberSecurity #InfoSec https://t.co/NndHJKON8A
@JNitterauer
28 Oct 2026
173 Impressions
0 Retweets
1 Like
0 Bookmarks
1 Reply
0 Quotes
Two more entries on CISA's KEV list, added 27 October with a federal due date of 10 November: Adobe Commerce and Magento (CVE-2026-48356) and Google Brotli (CVE-2026-111497). If a vendor's product bundles either, ask for their fix date in writing.
@ConsciousGRC
28 Oct 2026
5 Impressions
0 Retweets
0 Likes
0 Bookmarks
0 Replies
0 Quotes
CISA added CVE-2026-48356 in Adobe Commerce and Magento and CVE-2026-111497 in Google Brotli to its KEV Catalog based on evidence of active exploitation, urging organizations to prioritize remediation. https://t.co/ENlkBm9kNd
@TweetThreatNews
28 Oct 2026
214 Impressions
0 Retweets
0 Likes
0 Bookmarks
0 Replies
0 Quotes
🚨 Update: CISA added the Brotli "Node2Shell/HTTP2Shell" bug (CVE-2026-111497) to its exploited list Oct 27. Patch Brotli 1.2.1 and Node 22.23.4/24.22.1/26.12.1, then restart and rebuild container images. https://t.co/TxBCGNTXL2 #Node2Shell #Brotli #NodeJS #CISA #CVE #infosec
@TheLabLedger
28 Oct 2026
8 Impressions
0 Retweets
0 Likes
0 Bookmarks
1 Reply
0 Quotes
CISA KEV adds 2 actively exploited bugs: CVE-2026-48356 "PolyShell" in Magento/Adobe Commerce (hundreds of stores breached) + CVE-2026-111497 "Node2Shell" in Brotli, with live exploit traffic hitting Node.js. Patch Magento, upgrade Node & PHP now. #magent… https://t.co/Q9Hr
@4tifysecurity
28 Oct 2026
7 Impressions
0 Retweets
0 Likes
0 Bookmarks
0 Replies
0 Quotes
NØØT Exploitation Update Classification: Critical CVE: CVE-2026-111497 Product: out-of-bounds write in the Node.js Brotli decoder Summary: CVE-2026-111497: Critical out-of-bounds write in the Node.js Brotli decoder. Overview On October 21, 2026, the Node.js Project published
@Python_s_
28 Oct 2026
72 Impressions
0 Retweets
0 Likes
0 Bookmarks
0 Replies
0 Quotes
CISA added CVE-2026-111497 (Brotli) and CVE-2026-48356 (Adobe Commerce) to KEV. Exploit traffic for Node2Shell was observed from 94.154.43[.]7 while Magento stores face active PolyShell loader injections https://t.co/XJw8Tbnwlj https://t.co/QC14eBVf0C
@2Workly
28 Oct 2026
2 Impressions
0 Retweets
0 Likes
0 Bookmarks
0 Replies
0 Quotes
Paloaltoの脆弱性情報 「CVE-2026-111497 Portfolio Status: Impact of Brotli Vulnerability (CVE-2026-111497) on Palo Alto Networks Products (Severity: CRITICAL)」が公開されました。 → https://t.co/Gr0IhCllUL
@ripjyr
28 Oct 2026
363 Impressions
0 Retweets
1 Like
0 Bookmarks
0 Replies
0 Quotes
CVE-2026-111497、 実際問題、事業会社としてはどう対処すればいいの? 影響範囲が広すぎて、「CVE-2026-111497は潰しました~」なんて絶対に絶対に絶対に、言えないよ?
@Lost_Tanuki
28 Oct 2026
34 Impressions
0 Retweets
0 Likes
0 Bookmarks
0 Replies
0 Quotes
CVE-2026-111497 実際問題、事業会社としてはどう対処すればいいの? 影響範囲が広すぎて、「CVE-2026-111497は潰しました~」なんて絶対に絶対に絶対に、言えないよ?
@Lost_Tanuki
28 Oct 2026
2 Impressions
0 Retweets
0 Likes
0 Bookmarks
0 Replies
0 Quotes
Broccoli2Shell (CVE-2026-111497): Where Brotli Hides | Semgrep https://t.co/3SYt8zWL1w
@yactina1336
28 Oct 2026
29 Impressions
0 Retweets
0 Likes
0 Bookmarks
0 Replies
0 Quotes
【技術解説】あなたのアプリ、Brotliを解凍していませんか?Node.js超えで広がるCVE-2026-111497「Node2Shell」 Google Brotliのデコーダに境界外書き込み(CVE-2026-111497)。細工した圧縮データの解凍でクラッシュ〜RCE(Rem
@iss_kk_official
28 Oct 2026
69 Impressions
0 Retweets
0 Likes
0 Bookmarks
0 Replies
0 Quotes
【緊急】Brotli の脆弱性 CVE-2026-111497 の悪用を確認、CISA が KEV に追加 Google 製 Brotli デコーダの脆弱性(CVE-2026-111497)の悪用が確認されました。1.0.10・1.1.1・1.2.1 で修正済み。AL2023 は ALAS2023-2026-3334 で更新を。 https
@securitytopic
28 Oct 2026
10 Impressions
0 Retweets
0 Likes
0 Bookmarks
0 Replies
0 Quotes
【10/28 セキュリティ朝報】 圧縮ライブラリBrotliの脆弱性CVE-2026-111497をCISAがKEV追加。Node.jsは22.23.4/24.22.1/26.12.1へ更新を。 IDCFクラウドのランサム被害は、ポータル認証のOSS脆弱性が侵入口と公表。 https://t.co/JYoy
@salonyoza
28 Oct 2026
22 Impressions
0 Retweets
0 Likes
0 Bookmarks
1 Reply
0 Quotes
[
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:google:brotli:*:*:*:*:*:-:*:*",
"matchCriteriaId": "8A7BE60F-21B0-4779-8D59-6E5E58C5826B",
"versionEndExcluding": "1.0.10",
"versionStartIncluding": "1.0.3",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:google:brotli:*:*:*:*:*:-:*:*",
"matchCriteriaId": "48E72297-AFBD-4460-A732-5A6803CCCDB0",
"versionEndExcluding": "1.1.1",
"versionStartIncluding": "1.1.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:google:brotli:*:*:*:*:*:-:*:*",
"matchCriteriaId": "C8CA5C74-26A8-44E3-B893-1FA01CED49F5",
"versionEndExcluding": "1.2.1",
"versionStartIncluding": "1.2.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*",
"matchCriteriaId": "02348F18-5E17-4427-8B78-63B4082F2FB4",
"versionEndExcluding": "22.23.4",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*",
"matchCriteriaId": "852D09BB-A396-4813-81C9-7D89D5DD5FB6",
"versionEndExcluding": "24.22.1",
"versionStartIncluding": "23.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*",
"matchCriteriaId": "219CA855-3A40-42CE-BAB6-79CCFEE7746F",
"versionEndExcluding": "26.12.1",
"versionStartIncluding": "25.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:python-hyper:brotlicffi:*:*:*:*:*:python:*:*",
"matchCriteriaId": "E732E75B-4BEF-4D7E-8520-E03B707FB4F6",
"versionEndExcluding": "1.2.1.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:microsoft:.net:*:*:*:*:*:*:*:*",
"matchCriteriaId": "65DCE51C-2CD9-4179-9354-5323D28573AA",
"versionEndExcluding": "8.0.33",
"versionStartIncluding": "8.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:microsoft:.net:*:*:*:*:*:*:*:*",
"matchCriteriaId": "98654489-8C4E-4801-8728-29B01A22DEED",
"versionEndExcluding": "9.0.22",
"versionStartIncluding": "9.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:microsoft:.net:*:*:*:*:*:*:*:*",
"matchCriteriaId": "27DF5CF4-58E3-4F01-A3AA-D44B7DCC3D67",
"versionEndExcluding": "10.0.14",
"versionStartIncluding": "10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:microsoft:.net:11.0.0:preview1:*:*:*:*:*:*",
"matchCriteriaId": "5DACF2FE-CF61-43E4-8A3F-F7A358DE8A01",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:microsoft:.net:11.0.0:preview2:*:*:*:*:*:*",
"matchCriteriaId": "280B2E64-3163-40AB-A048-14D58DEC42FD",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:microsoft:.net:11.0.0:preview3:*:*:*:*:*:*",
"matchCriteriaId": "12357908-3294-46EF-85A0-DA3F86C97489",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:microsoft:.net:11.0.0:preview4:*:*:*:*:*:*",
"matchCriteriaId": "849FC8F5-86CD-4B5D-ADFD-9CB16EA75D09",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:microsoft:.net:11.0.0:preview5:*:*:*:*:*:*",
"matchCriteriaId": "C86E87E2-B236-4AC9-B6C3-64B9CDEC91EB",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:microsoft:.net:11.0.0:preview6:*:*:*:*:*:*",
"matchCriteriaId": "9B14656E-2BB0-4B4B-B518-F3D5108253ED",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:microsoft:.net:11.0.0:preview7:*:*:*:*:*:*",
"matchCriteriaId": "E09C9DB3-F42C-4442-9CF0-24A780D094C8",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:microsoft:.net:11.0.0:rc1:*:*:*:*:*:*",
"matchCriteriaId": "67035E86-61F5-421E-B243-EF64458AD8BA",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:microsoft:.net:11.0.0:rc2:*:*:*:*:*:*",
"matchCriteriaId": "C46300CA-BA84-48B3-85C5-C20CB487C733",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:debian:debian_linux:12.0:*:*:*:*:*:*:*",
"matchCriteriaId": "46D69DCC-AE4D-4EA5-861C-D60951444C6C",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:istio:istio:*:*:*:*:*:*:*:*",
"matchCriteriaId": "9F01FA9D-7190-431F-84DD-24D4EBC41A2D",
"versionEndExcluding": "1.29.9",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:istio:istio:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B8DE25CE-AFCB-4685-9836-B8EC9C820975",
"versionEndExcluding": "1.30.6",
"versionStartIncluding": "1.30.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:istio:istio:*:*:*:*:*:*:*:*",
"matchCriteriaId": "55EBE231-2EB8-4C9C-B279-D07F82EA5B55",
"versionEndExcluding": "1.31.2",
"versionStartIncluding": "1.31.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:anthropic:bun:*:*:*:*:*:*:*:*",
"matchCriteriaId": "51DD72B3-85F6-4B10-AEB4-41E0679ED0AA",
"versionEndExcluding": "1.4.4",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:envoyproxy:envoy:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8EE6278D-A48A-427C-8A7E-1D4103E2ADF7",
"versionEndExcluding": "1.37.8",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:envoyproxy:envoy:*:*:*:*:*:*:*:*",
"matchCriteriaId": "CDCA301F-83CA-4DDB-AAE4-24D5235EE2D5",
"versionEndExcluding": "1.38.6",
"versionStartIncluding": "1.38.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:envoyproxy:envoy:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B9A47DD3-2655-4722-9B9D-3888B590C82F",
"versionEndExcluding": "1.39.3",
"versionStartIncluding": "1.39.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:tianocore:edk2:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C4CFCBFB-4A38-481B-93AE-7D86CCDC6FB5",
"versionEndIncluding": "202608",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:google:woff2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "6D1FC23A-20F7-48F7-ABB8-8D37903DFB58",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:duckdb:duckdb:*:*:*:*:*:*:*:*",
"matchCriteriaId": "0DFA4F95-92F9-4369-BE42-387520F0765B",
"versionEndIncluding": "2.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:clickhouse:clickhouse:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B40EE389-E2AC-4D86-91B2-79A895470317",
"versionEndIncluding": "26.10.2.103",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:apache:arrow:*:*:*:*:*:*:*:*",
"matchCriteriaId": "46A78CA5-1E4A-4DAA-B40D-387B96C1E2F9",
"versionEndIncluding": "26.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:apache:arrow:27.0.0:dev:*:*:*:*:*:*",
"matchCriteriaId": "130A7077-7885-43CB-8AFF-B6056D380156",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:mcmilk:7-zip-zstd:*:*:*:*:*:*:*:*",
"matchCriteriaId": "FB91A353-9BE9-49E7-86FD-6B5FBB291351",
"versionEndIncluding": "26.02-1.5.7-r2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:7-zip:p7zip:*:*:*:*:*:*:*:*",
"matchCriteriaId": "76A26292-08BE-459A-B25A-CA14AF8D3C29",
"versionEndIncluding": "16.02",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:andybalholm:brotli:*:*:*:*:*:go:*:*",
"matchCriteriaId": "F3E50F12-AEFE-4B4F-B474-3676F145E032",
"versionEndExcluding": "1.2.7",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:ruggedcom_ape1808_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "37FDCA69-9049-40B4-88AF-F476901022B6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:ruggedcom_ape1808:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B89A6863-B602-4404-8D26-337FECABFFF0",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:common_configurator:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1F93AD0A-C29E-4FA6-A18B-1F0D03CC900C",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:data_flow_monitoring:*:*:*:*:*:*:*:*",
"matchCriteriaId": "3562BB8C-6E76-4B16-A2EF-D343EED30DA0",
"versionEndExcluding": "3.0.18",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:dataxess_configurator:*:*:*:*:*:*:*:*",
"matchCriteriaId": "076198F2-9992-4803-8377-8B264E1D7ADA",
"versionEndExcluding": "1.5.7",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:edge_opc_ua_server_configurator:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F1122EBA-DB7C-4680-AEEF-309C95843D0D",
"versionEndExcluding": "2.3.10",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:flow_creator_configurator:*:*:*:*:*:*:*:*",
"matchCriteriaId": "90BE4EB2-0B14-44F4-881D-F0DBAFCEF322",
"versionEndExcluding": "1.15.1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:industrial_edge_cloud_connector_configurator:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D0E0C6F6-40D0-4D71-ABCE-84449C4E743A",
"versionEndExcluding": "1.24.3",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:industrial_edge_databus_configurator:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B57AD29D-69CF-4C76-AACA-3EAE3F8CBC15",
"versionEndExcluding": "4.0.1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:industrial_edge_hub:-:*:*:*:*:*:*:*",
"matchCriteriaId": "70BA5718-0A9F-4B7D-9175-D6719B795363",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:industrial_edge_management_cloud:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4EA7E869-9428-4D5E-95C0-F19B6BC1BFA9",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:comos_walkinside:-:*:*:*:*:*:*:*",
"matchCriteriaId": "8C7AAED9-567F-4EE0-BC1B-F18E1109D316",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_braumat:8.2:update1:*:*:*:*:*:*",
"matchCriteriaId": "EFA8804E-1E7E-482F-A701-B988F6C0BCE9",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_braumat:8.2:update2:*:*:*:*:*:*",
"matchCriteriaId": "A7C12A3B-925A-4219-909B-6D2D0ADA6131",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_braumat:8.2:update3:*:*:*:*:*:*",
"matchCriteriaId": "3288CF66-F9D9-4DDD-9CAA-1EB2E075C87A",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_braumat:8.2:update4:*:*:*:*:*:*",
"matchCriteriaId": "9B3EF16B-8281-4159-ABDE-A36881CD8460",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_braumat:8.2:update5:*:*:*:*:*:*",
"matchCriteriaId": "9DF55BA1-F06B-4868-AC51-15ADC8BFED3C",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_profiling_tool:-:*:*:*:*:*:*:*",
"matchCriteriaId": "0D473CE5-B139-422C-AFCF-5FBBDB2C0759",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_sistar:8.2:update1:*:*:*:*:*:*",
"matchCriteriaId": "28A180EC-5DB8-4E8A-B063-813FA3973068",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_sistar:8.2:update2:*:*:*:*:*:*",
"matchCriteriaId": "31122237-42B0-4B10-B33B-D6E6DEBC19B3",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_sistar:8.2:update3:*:*:*:*:*:*",
"matchCriteriaId": "2955D58B-350F-4F96-A41F-6594639403DA",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_sistar:8.2:update4:*:*:*:*:*:*",
"matchCriteriaId": "0E95149C-B212-4670-8DFC-EEC713E87741",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_sistar:8.2:update5:*:*:*:*:*:*",
"matchCriteriaId": "173F36F4-23F4-4650-805F-25A9032AF64A",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:*",
"matchCriteriaId": "DA06F4BD-1512-4700-AD3E-25C6CDA60246",
"versionEndIncluding": "8.2",
"versionStartIncluding": "7.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_wincc_companion:-:*:*:*:*:-:*:*",
"matchCriteriaId": "174C0674-3100-4CCB-B55E-6BB1FB8F8442",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime:-:*:*:*:professional:*:*:*",
"matchCriteriaId": "E6BFBAED-EE2B-4DE4-A76C-824DD15F4608",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_wincc_unified_for_industrial_edge:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4DC1EDC8-DA6D-476F-9656-0FB9809F9E30",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_wincc_unified_pc_runtime:-:*:*:*:*:*:*:*",
"matchCriteriaId": "49B72BEA-DE75-4A5E-8658-30E5EBBFFF69",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_wincc_unified_siqence:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E2E193FF-ED70-432A-8B33-2453A8B2B21B",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:tia_administrator:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FC8C7680-9033-4ECF-9764-5179A4033F64",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:tia_project-server_web_administration_tool:-:*:*:*:*:*:*:*",
"matchCriteriaId": "14BA6E1D-4D4E-4133-8869-5ADEC9CE545C",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:user_management_component:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7139EEDB-2DCD-4C55-9DAC-423FB5807D11",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:hyperlynx:-:*:*:*:*:*:*:*",
"matchCriteriaId": "92D6ED26-34E3-46A6-B025-F7DC263AA75A",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:innexis_architecture_native_acceleration:-:*:*:*:*:*:*:*",
"matchCriteriaId": "BE57EA6F-BA70-409D-B037-EDD603FAC0B9",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:insights_hub:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1B8E91A0-4BF0-4BDE-8F83-4FF374697A76",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:opcenter_connect_electronics:-:*:*:*:*:*:*:*",
"matchCriteriaId": "0EC96381-D0C9-4949-86E7-1A1E8239A8F2",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:opcenter_connect_manufacturing_operations_management:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B0F5FAC2-E6E0-4ECA-86B6-9D082C1D674B",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:opcenter_execution_core:-:*:*:*:*:*:*:*",
"matchCriteriaId": "0A6E1786-F0A9-498F-9DE9-F503B5DAD84A",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:opcenter_execution_discrete:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F04BAB87-71BB-4AB4-BC42-F89616698EEF",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:opcenter_execution_foundation:-:*:*:*:*:*:*:*",
"matchCriteriaId": "9FE353B7-07A1-4B50-8A43-62577C2208EE",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:opcenter_execution_pharma:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4CC50DA8-906E-4BD5-9861-668273EE3A76",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:opcenter_execution_process:-:*:*:*:*:*:*:*",
"matchCriteriaId": "5CCA2643-1E89-49AE-B8CB-3A9CDA3031A6",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:opcenter_intelligence:-:*:*:*:*:*:*:*",
"matchCriteriaId": "8E3FA7CB-6931-4D0C-A3E6-1BE71EA0D30F",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:opcenter_quality:-:*:*:*:*:*:*:*",
"matchCriteriaId": "9D9D89CD-FDA5-42F0-8161-3752C8AED7F3",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:opcenter_rd\\&l:-:*:*:*:*:*:*:*",
"matchCriteriaId": "69EDC5E0-6CCE-4120-913C-E598E0FE2D24",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:opcenter_x:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A12051E1-2DC9-47C6-A320-927D0A7B9F47",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:pads_professional:-:*:*:*:essentials:*:*:*",
"matchCriteriaId": "C9033337-D032-403D-8BBF-3EA50253A40E",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:pads_professional:-:*:*:*:student:*:*:*",
"matchCriteriaId": "F06B80D2-6A35-4AF5-A07A-0F5C3370C3E7",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:pave360_automotive:2026:*:*:*:*:*:*:*",
"matchCriteriaId": "B8DBFD9C-B213-4238-B39C-D4B537523CB1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:process_preparation_x:-:*:*:*:-:*:*:*",
"matchCriteriaId": "FEBDB60C-D759-476D-AF06-3C0691FC72CF",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simcenter_executable_digital_twin:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F6ACF933-A876-4DE5-BBA7-D5BF97DB1AB4",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simcenter_studio:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B8C684EC-BECB-4833-B1F9-F773225A6172",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:teamcenter:2412.0:*:*:*:*:*:*:*",
"matchCriteriaId": "963C8AAA-D3E0-4B10-93AE-DB15619EC5EE",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:teamcenter:2506.0:*:*:*:*:*:*:*",
"matchCriteriaId": "261C46FE-1C63-4A1F-8C8E-FC331E8F119E",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:teamcenter:2512.0:*:*:*:*:*:*:*",
"matchCriteriaId": "7946C16C-5B81-42D2-BA6D-C8AA8FD5AD0C",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:teamcenter:2606.0:*:*:*:*:*:*:*",
"matchCriteriaId": "86E64B27-FE8F-45AD-BE78-219E4067F8DE",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:xpedition_designer:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F52F6405-0228-4C3D-842F-839192076657",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:xpedition_enterprise:-:*:*:*:*:*:*:*",
"matchCriteriaId": "AD525494-2807-48EA-AED0-11B9CB5A6A9B",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
]