- Description
- A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 6). The affected application uses a password hashing implementation with a static, hardcoded salt shared across all users and installations, and is configured with an insufficient number of iterations. This could allow an attacker to efficiently recover user passwords using brute-force or precomputed attacks, potentially resulting in unauthorized access.
- Source
- productcert@siemens.com
- NVD status
- Analyzed
- Products
- sinec_ins
CVSS 4.0
- Type
- Secondary
- Base score
- 4.9
- Impact score
- -
- Exploitability score
- -
- Vector string
- CVSS:4.0/AV:L/AC:H/AT:P/PR:H/UI:N/VC:L/VI:N/VA:N/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Severity
- MEDIUM
CVSS 3.1
- Type
- Primary
- Base score
- 9.8
- Impact score
- 5.9
- Exploitability score
- 3.9
- Vector string
- CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
- Severity
- CRITICAL
- productcert@siemens.com
- CWE-760
- Hype score
- Not currently trending
[
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:sinec_ins:*:-:*:*:*:*:*:*",
"matchCriteriaId": "B0309582-8D59-405A-886D-158C25B8B281",
"versionEndIncluding": "1.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:sinec_ins:1.0:sp1:*:*:*:*:*:*",
"matchCriteriaId": "75BC588E-CDF0-404E-AD61-02093A1DF343",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:sinec_ins:1.0:sp2:*:*:*:*:*:*",
"matchCriteriaId": "A334F7B4-7283-4453-BAED-D2E01B7F8A6E",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:sinec_ins:1.0:sp2_update_1:*:*:*:*:*:*",
"matchCriteriaId": "A6BEA71C-CA81-4B5D-A688-2B21E62DC351",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:sinec_ins:1.0:sp2_update_2:*:*:*:*:*:*",
"matchCriteriaId": "6B405F22-5517-49F5-A7CA-1E50D58DFC75",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:sinec_ins:1.0:sp2_update_3:*:*:*:*:*:*",
"matchCriteriaId": "10CD32A2-3109-4933-84B5-FFE350E7C741",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:sinec_ins:1.0:sp2_update_4:*:*:*:*:*:*",
"matchCriteriaId": "520B52FE-DE36-445F-ABFE-52B34DE7E00C",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:sinec_ins:1.0:sp2_update_5:*:*:*:*:*:*",
"matchCriteriaId": "862C9F93-4E58-4B70-97D2-9FBBCE34DBC3",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
]