- Description
- CWE-522 Insufficiently Protected Credentials vulnerability that could cause unauthorized access and exposure of sensitive information when unauthenticated attacker accesses credentials stored within firmware or system files. With this credential an attacker could subsequently compromise the device if they have physical access to the device.
- Source
- cybersecurity@se.com
- NVD status
- Analyzed
- Products
- easylogic_t150_firmware, saitel_dp_firmware
CVSS 4.0
- Type
- Secondary
- Base score
- 8.7
- Impact score
- -
- Exploitability score
- -
- Vector string
- CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Severity
- HIGH
CVSS 3.1
- Type
- Primary
- Base score
- 7.5
- Impact score
- 3.6
- Exploitability score
- 3.9
- Vector string
- CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
- Severity
- HIGH
- cybersecurity@se.com
- CWE-522
- Hype score
- Not currently trending
[
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:easylogic_t150_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "6D498A9B-1593-41C1-BB95-F7815F01087D",
"versionEndExcluding": "11.06.32",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:easylogic_t150:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E3B30463-195D-4D26-BC9E-9BA0D9BBB862",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:saitel_dp_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "71B582C0-A3F2-4E6F-B2CE-E77ACB81F59F",
"versionEndExcluding": "11.06.38",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:saitel_dp:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E6D73382-1957-4CC7-953F-D57C005D63B0",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
]