- Description
- The SMBv1 server in Microsoft Windows Vista SP2; Windows Server 2008 SP2 and R2 SP1; Windows 7 SP1; Windows 8.1; Windows Server 2012 Gold and R2; Windows RT 8.1; and Windows 10 Gold, 1511, and 1607; and Windows Server 2016 allows remote attackers to execute arbitrary code via crafted packets, aka "Windows SMB Remote Code Execution Vulnerability." This vulnerability is different from those described in CVE-2017-0143, CVE-2017-0144, CVE-2017-0146, and CVE-2017-0148.
- Source
- secure@microsoft.com
- NVD status
- Analyzed
- Products
- server_message_block, acuson_p300_firmware, acuson_p500_firmware, acuson_sc2000_firmware, acuson_x700_firmware, syngo_sc2000_firmware, tissue_preparation_system_firmware, versant_kpcr_molecular_system_firmware, versant_kpcr_sample_prep_firmware
CVSS 3.1
- Type
- Primary
- Base score
- 8.8
- Impact score
- 5.9
- Exploitability score
- 2.8
- Vector string
- CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
- Severity
- HIGH
CVSS 2.0
- Type
- Primary
- Base score
- 9.3
- Impact score
- 10
- Exploitability score
- 8.6
- Vector string
- AV:N/AC:M/Au:N/C:C/I:C/A:C
Data from CISA
- Vulnerability name
- Microsoft SMBv1 Remote Code Execution Vulnerability
- Exploit added on
- Feb 10, 2022
- Exploit action due
- Aug 10, 2022
- Required action
- Apply updates per vendor instructions.
- Hype score
- Not currently trending
[
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:microsoft:server_message_block:1.0:*:*:*:*:*:*:*",
"matchCriteriaId": "EFFA22FC-A15A-4EB5-BED7-45F6EAFA8F80",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:microsoft:windows_10_1507:-:*:*:*:*:*:*:*",
"matchCriteriaId": "542DAEEC-73CC-46C6-A630-BF474A3446AC",
"vulnerable": false
},
{
"criteria": "cpe:2.3:o:microsoft:windows_10_1511:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7A8E9D99-BD78-4340-88F2-5AFF27AC37C9",
"vulnerable": false
},
{
"criteria": "cpe:2.3:o:microsoft:windows_10_1607:-:*:*:*:*:*:*:*",
"matchCriteriaId": "61019899-D7AF-46E4-A72C-D189180F66AB",
"vulnerable": false
},
{
"criteria": "cpe:2.3:o:microsoft:windows_7:-:sp1:*:*:*:*:*:*",
"matchCriteriaId": "C2B1C231-DE19-4B8F-A4AA-5B3A65276E46",
"vulnerable": false
},
{
"criteria": "cpe:2.3:o:microsoft:windows_8.1:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E93068DB-549B-45AB-8E5C-00EB5D8B5CF8",
"vulnerable": false
},
{
"criteria": "cpe:2.3:o:microsoft:windows_rt_8.1:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C6CE5198-C498-4672-AF4C-77AB4BE06C5C",
"vulnerable": false
},
{
"criteria": "cpe:2.3:o:microsoft:windows_server_2008:-:sp2:*:*:*:*:*:*",
"matchCriteriaId": "5F422A8C-2C4E-42C8-B420-E0728037E15C",
"vulnerable": false
},
{
"criteria": "cpe:2.3:o:microsoft:windows_server_2008:r2:sp1:*:*:*:*:*:*",
"matchCriteriaId": "2ACA9287-B475-4AF7-A4DA-A7143CEF9E57",
"vulnerable": false
},
{
"criteria": "cpe:2.3:o:microsoft:windows_server_2012:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A7DF96F8-BA6A-4780-9CA3-F719B3F81074",
"vulnerable": false
},
{
"criteria": "cpe:2.3:o:microsoft:windows_server_2012:r2:*:*:*:*:*:*:*",
"matchCriteriaId": "DB18C4CE-5917-401E-ACF7-2747084FD36E",
"vulnerable": false
},
{
"criteria": "cpe:2.3:o:microsoft:windows_server_2016:-:*:*:*:*:*:*:*",
"matchCriteriaId": "041FF8BA-0B12-4A1F-B4BF-9C4F33B7C1E7",
"vulnerable": false
},
{
"criteria": "cpe:2.3:o:microsoft:windows_vista:-:sp2:*:*:*:*:*:*",
"matchCriteriaId": "BF1AD1A1-EE20-4BCE-9EE6-84B27139811C",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:acuson_p300_firmware:13.02:*:*:*:*:*:*:*",
"matchCriteriaId": "0814F7B8-8022-4DCC-BE37-4868EB912881",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:siemens:acuson_p300_firmware:13.03:*:*:*:*:*:*:*",
"matchCriteriaId": "87A45473-9558-4165-949B-D63F1486F28E",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:siemens:acuson_p300_firmware:13.20:*:*:*:*:*:*:*",
"matchCriteriaId": "59E3D131-8FDF-424C-9BBA-41FDAE43F24C",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:siemens:acuson_p300_firmware:13.21:*:*:*:*:*:*:*",
"matchCriteriaId": "2C270FA0-6961-4181-8388-E609DAEADC09",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:acuson_p300:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C07C8A47-9E8F-42E4-BB35-64590853A9C5",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:acuson_p500_firmware:va10:*:*:*:*:*:*:*",
"matchCriteriaId": "506F5373-3C3C-4F47-8FC0-D5F04095B324",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:siemens:acuson_p500_firmware:vb10:*:*:*:*:*:*:*",
"matchCriteriaId": "42DBCB0C-2C71-4427-ADF8-FCB4920609B7",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:acuson_p500:-:*:*:*:*:*:*:*",
"matchCriteriaId": "3C50335A-8742-4E2B-B22D-0ED0A0DFB5C4",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:acuson_sc2000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D4CFBFA2-BDE4-4566-A435-92BFB87C48E8",
"versionEndExcluding": "4.0e",
"versionStartIncluding": "4.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:siemens:acuson_sc2000_firmware:5.0a:*:*:*:*:*:*:*",
"matchCriteriaId": "7DFBC156-20D1-4546-948F-A2118D602137",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:acuson_sc2000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "70575FD4-0A0A-4D11-9069-F808D9F00D10",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:acuson_x700_firmware:1.0:*:*:*:*:*:*:*",
"matchCriteriaId": "B1E644CD-EA9B-45B5-A7C6-5F294D8A6909",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:siemens:acuson_x700_firmware:1.1:*:*:*:*:*:*:*",
"matchCriteriaId": "4F38DAB6-39E2-4048-A57D-C3EB8415F3F2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:acuson_x700:-:*:*:*:*:*:*:*",
"matchCriteriaId": "05BD2983-B780-46F0-A857-CFC614D1B524",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:syngo_sc2000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "99A99C16-9C4C-4BFF-B60A-A7BB67D7D397",
"versionEndExcluding": "4.0e",
"versionStartIncluding": "4.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:siemens:syngo_sc2000_firmware:5.0a:*:*:*:*:*:*:*",
"matchCriteriaId": "1753DB4B-1F5A-4193-A50C-C2A576F0884C",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:syngo_sc2000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "25CEAC4F-CBA5-41BA-B389-4D0DA3F85B59",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:tissue_preparation_system_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "6DE83393-E735-42BC-86E9-5DAF9F403C73",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:tissue_preparation_system:-:*:*:*:*:*:*:*",
"matchCriteriaId": "5641B967-9938-4148-90C4-D92C3E757847",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:versant_kpcr_molecular_system_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "582D4D5C-D0F1-403D-8687-3F1491943A65",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:versant_kpcr_molecular_system:-:*:*:*:*:*:*:*",
"matchCriteriaId": "68FE5E09-78BB-4A22-9CAA-93ECD7AC33A4",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:versant_kpcr_sample_prep_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "AA7B7CC4-E89E-4357-A7D6-AF74480F46B5",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:versant_kpcr_sample_prep:-:*:*:*:*:*:*:*",
"matchCriteriaId": "41EF3913-CD35-49FD-90D8-62228DB1390C",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
]