- Description
- A vulnerability has been identified in Solid Edge SE2024 (All versions < V224.0 Update 12), Solid Edge SE2025 (All versions < V225.0 Update 3). The affected application contains an out of bounds write past the end of an allocated buffer while parsing X_T data or a specially crafted file in X_T format. This could allow an attacker to execute code in the context of the current process.
- Source
- productcert@siemens.com
- NVD status
- Analyzed
- Products
- parasolid, solid_edge_se2024, solid_edge_se2025
CVSS 4.0
- Type
- Secondary
- Base score
- 7.3
- Impact score
- -
- Exploitability score
- -
- Vector string
- CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Severity
- HIGH
CVSS 3.1
- Type
- Secondary
- Base score
- 7.8
- Impact score
- 5.9
- Exploitability score
- 1.8
- Vector string
- CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
- Severity
- HIGH
- productcert@siemens.com
- CWE-787
- Hype score
- Not currently trending
CVE-2024-54091 Out-of-Bounds Write in Parasolid Allows Code Execution Parasolid has a problem in V36.1, V37.0, and V37.1 if they are below certain versions. This problem is an out of bounds write vulnerability. I... https://t.co/vPe7HJMPx5
@VulmonFeeds
10 Dec 2024
42 Impressions
0 Retweets
0 Likes
0 Bookmarks
0 Replies
0 Quotes
CVE-2024-54091 A vulnerability has been identified in Parasolid V36.1 (All versions < V36.1.225), Parasolid V37.0 (All versions < V37.0.173), Parasolid V37.1 (All versions < V37.1.1… https://t.co/KfIe38v7dU
@CVEnew
10 Dec 2024
222 Impressions
0 Retweets
0 Likes
0 Bookmarks
0 Replies
0 Quotes
[
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D20F4CD4-F876-4743-A15B-99B0085AF013",
"versionEndExcluding": "36.1.225",
"versionStartIncluding": "36.1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*",
"matchCriteriaId": "CD7F5D01-5253-4C5A-A399-6E4D2EE1CD1D",
"versionEndExcluding": "37.0.173",
"versionStartIncluding": "37.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:-:*:*:*:*:*:*:*",
"matchCriteriaId": "893736B3-0140-4775-8700-CB9D7719DDE5",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:-:*:*:*:*:*:*",
"matchCriteriaId": "A0119E8F-1FAF-4A3B-B6E9-20F78360FC82",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0001:*:*:*:*:*:*",
"matchCriteriaId": "829C4AEB-7C8D-408B-A79C-8684753F45E1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_00010:*:*:*:*:*:*",
"matchCriteriaId": "8E262AB3-8C47-430A-9D42-89317CB630C5",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_00011:*:*:*:*:*:*",
"matchCriteriaId": "94758C94-F427-480E-A9F1-109D8660C4E0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0002:*:*:*:*:*:*",
"matchCriteriaId": "1E8FB23E-280D-46FD-BD44-5D4552639E00",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0003:*:*:*:*:*:*",
"matchCriteriaId": "CA2417A0-DD31-46FC-8D5A-9128B86C9352",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0004:*:*:*:*:*:*",
"matchCriteriaId": "3CA9C494-767C-4CFA-AB07-106298B7B2C4",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0005:*:*:*:*:*:*",
"matchCriteriaId": "C3738D73-82A5-41E4-8083-34611A6301BE",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0006:*:*:*:*:*:*",
"matchCriteriaId": "5634352F-0DD1-4731-9E43-61D0A9A40D1B",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0007:*:*:*:*:*:*",
"matchCriteriaId": "32E3D549-54F0-4909-830D-BDE8CDAD5AF7",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0008:*:*:*:*:*:*",
"matchCriteriaId": "1137D7B3-17AD-4997-AC19-4308AA5C9438",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0009:*:*:*:*:*:*",
"matchCriteriaId": "E5488DEB-3165-4F88-8C63-7B9BC212DEFF",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2025:-:*:*:*:*:*:*:*",
"matchCriteriaId": "9EBC379B-A9D5-4587-87A1-59D2D8EF2267",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2025:225.0:-:*:*:*:*:*:*",
"matchCriteriaId": "3D717792-2F86-43CD-973B-249171094C6C",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2025:225.0:update_0001:*:*:*:*:*:*",
"matchCriteriaId": "2C6F3C20-8AB5-4A6A-8524-C7CBC4A4D973",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2025:225.0:update_0002:*:*:*:*:*:*",
"matchCriteriaId": "03CCA3A8-F8D6-4C80-BC03-15B865CE46B7",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2025:225.0:update_0003:*:*:*:*:*:*",
"matchCriteriaId": "B51556E8-9A3B-4755-BC2C-8FACABC01A7B",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
]