SCADA vulnerabilities
Showing 101 - 146 of 146 CVEs
- CVE-2023-28400 Published Apr 27, 2023
mySCADA myPRO versions 8.26.0 and prior has parameters which an authenticated user could exploit to inject arbitrary operating system commands.
- CVE-2023-28384 Published Apr 27, 2023
mySCADA myPRO versions 8.26.0 and prior has parameters which an authenticated user could exploit to inject arbitrary operating system commands.
- CVE-2023-28756 Published Mar 31, 2023
A ReDoS issue was discovered in the Time component through 0.2.1 in Ruby through 3.2.1. The Time parser mishandles invalid URLs that have specific characters. It causes an increase in execution time for parsing strings to Time objects. The fixed versions are 0.1.1 and 0.2.2.
- CVE-2023-28755 Published Mar 31, 2023
A ReDoS issue was discovered in the URI component through 0.12.0 in Ruby through 3.2.1. The URI parser mishandles invalid URLs that have specific characters. It causes an increase in execution time for parsing strings to URI objects. The fixed versions are 0.12.1, 0.11.1, 0.10.2 and 0.10.0.1.
- CVE-2023-27394 Published Mar 28, 2023
Osprey Pump Controller version 1.01 is vulnerable an unauthenticated OS command injection vulnerability. This can be exploited to inject and execute arbitrary shell commands through a HTTP GET parameter called by DataLogView.php, EventsView.php and AlarmsView.php scripts.
- CVE-2022-3682 Published Mar 28, 2023
A vulnerability exists in the SDM600 file permission validation. An attacker could exploit the vulnerability by gaining access to the system and uploading a specially crafted message to the system node, which could result in Arbitrary code Executing. This issue affects: All SDM600 versions prior to version 1.2 FP3 HF4 (Build Nr. 1.2.23000.291) List of CPEs: * cpe:2.3:a:hitachienergy:sdm600:1.0:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.1:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.9002.257:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.10002.257:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.11002.149:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.12002.222:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.13002.72:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.44:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.92:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.108:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.182:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.257:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.342:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.447:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.481:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.506:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.566:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.20000.3174:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.21000.291:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.21000.931:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.21000.105:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.23000.291:*:*:*:*:*:*:*
- CVE-2023-1256 Published Mar 16, 2023
The listed versions of AVEVA Plant SCADA and AVEVA Telemetry Server are vulnerable to an improper authorization exploit which could allow an unauthenticated user to remotely read data, cause denial of service, and tamper with alarm states.
- CVE-2023-22424 Published Mar 6, 2023
Use-after-free vulnerability exists in Kostac PLC Programming Software (Former name: Koyo PLC Programming Software) Version 1.6.9.0 and earlier. With the abnormal value given as the maximum number of columns for the PLC program, the process accesses the freed memory. As a result, opening a specially crafted project file may lead to information disclosure and/or arbitrary code execution.
- CVE-2023-22421 Published Mar 6, 2023
Out-of-bounds read vulnerability exists in Kostac PLC Programming Software (Former name: Koyo PLC Programming Software) Version 1.6.9.0 and earlier. The insufficient buffer size for the PLC program instructions leads to out-of-bounds read. As a result, opening a specially crafted project file may lead to information disclosure and/or arbitrary code execution.
- CVE-2023-22419 Published Mar 6, 2023
Out-of-bounds read vulnerability exists in Kostac PLC Programming Software (Former name: Koyo PLC Programming Software) Version 1.6.9.0 and earlier. When processing a comment block in stage information, the end of data cannot be verified and out-of-bounds read occurs. As a result, opening a specially crafted project file may lead to information disclosure and/or arbitrary code execution.
- CVE-2023-23296 Published Feb 23, 2023
Korenix JetWave 4200 Series 1.3.0 and JetWave 3200 Series 1.6.0 are vulnerable to Denial of Service via /goform/formDefault.
- CVE-2023-23294 Published Feb 23, 2023
Korenix JetWave 4200 Series 1.3.0 and JetWave 3000 Series 1.6.0 are vulnerable to Command Injection. An attacker can modify the file_name parameter to execute commands as root.
- CVE-2023-23295 Published Feb 23, 2023
Korenix Jetwave 4200 Series 1.3.0 and JetWave 3000 Series 1.6.0 are vulnerable to Command Injection via /goform/formSysCmd. An attacker an modify the sysCmd parameter in order to execute commands as root.
- CVE-2022-3270 Published Dec 1, 2022
In multiple products by Festo a remote unauthenticated attacker could use functions of an undocumented protocol which could lead to a complete loss of confidentiality, integrity and availability.
- CVE-2022-40799 Published Nov 29, 2022
Data Integrity Failure in 'Backup Config' in D-Link DNR-322L <= 2.60B15 allows an authenticated attacker to execute OS level commands on the device.
- CVE-2022-3181 Published Nov 2, 2022
An Improper Input Validation vulnerability exists in Trihedral VTScada version 12.0.38 and prior. A specifically malformed HTTP request could cause the affected VTScada to crash. Both local area network (LAN)-only and internet facing systems are affected.
- CVE-2022-37300 Published Sep 12, 2022
A CWE-640: Weak Password Recovery Mechanism for Forgotten Password vulnerability exists that could cause unauthorized access in read and write mode to the controller when communicating over Modbus. Affected Products: EcoStruxure Control Expert Including all Unity Pro versions (former name of EcoStruxure Control Expert) (V15.0 SP1 and prior), EcoStruxure Process Expert, Including all versions of EcoStruxure Hybrid DCS (former name of EcoStruxure Process Expert) (V2021 and prior), Modicon M340 CPU (part numbers BMXP34*) (V3.40 and prior), Modicon M580 CPU (part numbers BMEP* and BMEH*) (V3.20 and prior).
- CVE-2020-25184 Published Mar 18, 2022
Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x stores the password in plaintext in a file that is in the same directory as the executable file. ISaGRAF Runtime reads the file and saves the data in a variable without any additional modification. A local, unauthenticated attacker could compromise the user passwords, resulting in information disclosure.
- CVE-2020-25182 Published Mar 18, 2022
Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x searches for and loads DLLs as dynamic libraries. Uncontrolled loading of dynamic libraries could allow a local, unauthenticated attacker to execute arbitrary code. This vulnerability only affects ISaGRAF Runtime when running on Microsoft Windows systems.
- CVE-2020-25180 Published Mar 18, 2022
Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x includes the functionality of setting a password that is required to execute privileged commands. The password value passed to ISaGRAF Runtime is the result of encryption performed with a fixed key value using the tiny encryption algorithm (TEA) on an entered or saved password. A remote, unauthenticated attacker could pass their own encrypted password to the ISaGRAF 5 Runtime, which may result in information disclosure on the device.
- CVE-2022-25359 Published Feb 26, 2022
On ICL ScadaFlex II SCADA Controller SC-1 and SC-2 1.03.07 devices, unauthenticated remote attackers can overwrite, delete, or create files.
- CVE-2022-23921 Published Feb 25, 2022
Exploitation of this vulnerability may result in local privilege escalation and code execution. GE maintains exploitation of this vulnerability is only possible if the attacker has login access to a machine actively running CIMPLICITY, the CIMPLICITY server is not already running a project, and the server is licensed for multiple projects.
- CVE-2022-21798 Published Feb 25, 2022
The affected product is vulnerable due to cleartext transmission of credentials seen in the CIMPLICITY network, which can be easily spoofed and used to log in to make operational changes to the system.
- CVE-2022-24316 Published Feb 9, 2022
A CWE-665: Improper Initialization vulnerability exists that could cause information exposure when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)
- CVE-2022-23130 Published Jan 21, 2022
Buffer Over-read vulnerability in Mitsubishi Electric MC Works64 versions 4.00A to 4.04E, Mitsubishi Electric GENESIS64 versions 10.97 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 and prior, Mitsubishi Electric ICONICS Suite versions 10.97 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 and prior, Mitsubishi Electric GENESIS32 versions 9.7 and prior, and Mitsubishi Electric Iconics Digital Solutions GENESIS32 versions 9.7 and prior allows an attacker to cause a DoS condition in the database server by getting a legitimate user to import a configuration file containing specially crafted stored procedures into GENESIS64, ICONICS Suite, MC Works64, or GENESIS32 and execute commands against the database from GENESIS64, ICONICS Suite, MC Works64, or GENESIS32.
- CVE-2022-23129 Published Jan 21, 2022
Plaintext Storage of a Password vulnerability in Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior and ICONICS GENESIS64 versions 10.90 to 10.97 allows a local authenticated attacker to gain authentication information and to access the database illegally. This is because when configuration information of GridWorX, a database linkage function of GENESIS64 and MC Works64, is exported to a CSV file, the authentication information is saved in plaintext, and an attacker who can access this CSV file can gain the authentication information.
- CVE-2022-23128 Published Jan 21, 2022
Incomplete List of Disallowed Inputs vulnerability in Mitsubishi Electric MC Works64 versions 4.00A (10.95.201.23) to 4.04E (10.95.210.01), ICONICS GENESIS64 versions 10.95.3 to 10.97, ICONICS Hyper Historian versions 10.95.3 to 10.97, ICONICS AnalytiX versions 10.95.3 to 10.97 and ICONICS MobileHMI versions 10.95.3 to 10.97 allows a remote unauthenticated attacker to bypass the authentication of MC Works64, GENESIS64, Hyper Historian, AnalytiX and MobileHMI, and gain unauthorized access to the products, by sending specially crafted WebSocket packets to FrameWorX server, one of the functions of the products.
- CVE-2022-23127 Published Jan 21, 2022
Cross-site Scripting vulnerability in Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior and ICONICS MobileHMI versions 10.96.2 and prior allows a remote unauthenticated attacker to gain authentication information of an MC Works64 or MobileHMI and perform any operation using the acquired authentication information, by injecting a malicious script in the URL of a monitoring screen delivered from the MC Works64 server or MobileHMI server to an application for mobile devices and leading a legitimate user to access this URL.
- CVE-2021-42707 Published Nov 22, 2021
PLC Editor Versions 1.3.8 and prior is vulnerable to an out-of-bounds write while processing project files, which may allow an attacker to execute arbitrary code.
- CVE-2021-38406 Published Sep 17, 2021
Delta Electronic DOPSoft 2 (Version 2.00.07 and prior) lacks proper validation of user-supplied data when parsing specific project files. This could result in multiple out-of-bounds write instances. An attacker could leverage this vulnerability to execute code in the context of the current process.
- CVE-2021-26829 Published Jun 11, 2021
OpenPLC ScadaBR through 0.9.1 on Linux and through 1.12.4 on Windows allows stored XSS via system_settings.shtm.
- CVE-2021-26828 Published Jun 11, 2021
OpenPLC ScadaBR through 0.9.1 on Linux and through 1.12.4 on Windows allows remote authenticated users to upload and execute arbitrary JSP files via view_edit.shtm.
- CVE-2020-25161 Published Feb 23, 2021
The WADashboard component of WebAccess/SCADA Versions 9.0 and prior may allow an attacker to control or influence a path used in an operation on the filesystem and remotely execute code as an administrator.
- CVE-2020-25181 Published Dec 1, 2020
WECON PLC Editor Versions 1.3.8 and prior has a heap-based buffer overflow vulnerabilities have been identified that may allow arbitrary code execution.
- CVE-2020-25177 Published Dec 1, 2020
WECON PLC Editor Versions 1.3.8 and prior has a stack-based buffer overflow vulnerability has been identified that may allow arbitrary code execution.
- CVE-2020-25159 Published Nov 24, 2020
499ES EtherNet/IP (ENIP) Adaptor Source Code is vulnerable to a stack-based buffer overflow, which may allow an attacker to send a specially crafted packet that may result in a denial-of-service condition or code execution.
- CVE-2020-13501 Published Sep 24, 2020
An SQL injection vulnerability exists in the CHaD.asmx web service functionality of eDNA Enterprise Data Historian 3.0.1.2/7.5.4989.33053. Specially crafted SOAP web requests can cause SQL injections resulting in data compromise. Parameter InstanceName in CHaD.asmx is vulnerable to unauthenticated SQL injection attacks.
- CVE-2020-13500 Published Sep 24, 2020
SQL injection vulnerability exists in the CHaD.asmx web service functionality of eDNA Enterprise Data Historian 3.0.1.2/7.5.4989.33053. Specially crafted SOAP web requests can cause SQL injections resulting in data compromise. Parameter ClassName in CHaD.asmx is vulnerable to unauthenticated SQL injection attacks.
- CVE-2020-13499 Published Sep 24, 2020
An SQL injection vulnerability exists in the CHaD.asmx web service functionality of eDNA Enterprise Data Historian 3.0.1.2/7.5.4989.33053. Specially crafted SOAP web requests can cause SQL injections resulting in data compromise. Parameter InstancePath in CHaD.asmx is vulnerable to unauthenticated SQL injection attacks.
- CVE-2020-25079 Published Sep 2, 2020
An issue was discovered on D-Link DCS-2530L before 1.06.01 Hotfix and DCS-2670L through 2.02 devices. cgi-bin/ddns_enc.cgi allows authenticated command injection.
- CVE-2020-25078 Published Sep 2, 2020
An issue was discovered on D-Link DCS-2530L before 1.06.01 Hotfix and DCS-2670L through 2.02 devices. The unauthenticated /config/getuser endpoint allows for remote administrator password disclosure.
- CVE-2020-22722 Published Aug 14, 2020
Rapid Software LLC Rapid SCADA 5.8.0 is affected by a local privilege escalation vulnerability in the ScadaAgentSvc.exe executable file. An attacker can obtain admin privileges by placing a malicious .exe file in the application and renaming it ScadaAgentSvc.exe, which would result in executing the binary as NT AUTHORITY\SYSTEM in a Windows operating system. For example, an attacker can plant a reverse shell from a low privileged user account and by restarting the computer, the malicious service will be started as NT AUTHORITY\SYSTEM by giving the attacker full system access to the remote PC.
- CVE-2020-15368 Published Jun 29, 2020
AsrDrv103.sys in the ASRock RGB Driver does not properly restrict access from user space, as demonstrated by triggering a triple fault via a request to zero CR3.
- CVE-2020-10615 Published Apr 15, 2020
Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers cause a denial-of-service condition due to a lack of proper validation of the length of user-supplied data, prior to copying it to a fixed-length stack-based buffer. Authentication is not required to exploit this vulnerability.
- CVE-2020-10611 Published Apr 15, 2020
Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers to execute arbitrary code due to the lack of proper validation of user-supplied data, which can result in a type confusion condition. Authentication is not required to exploit this vulnerability. Only applicable to installations using DNP3 Data Sets.
- CVE-2020-7479 Published Mar 23, 2020
A CWE-306: Missing Authentication for Critical Function vulnerability exists in IGSS (Versions 14 and prior using the service: IGSSupdate), which could allow a local user to execute processes that otherwise require escalation privileges when sending local network commands to the IGSS Update Service.
mySCADA myPRO versions 8.26.0 and prior has parameters which an authenticated user could exploit to inject arbitrary operating system commands.
high 8.8
mySCADA myPRO versions 8.26.0 and prior has parameters which an authenticated user could exploit to inject arbitrary operating system commands.
high 8.8
A ReDoS issue was discovered in the Time component through 0.2.1 in Ruby through 3.2.1. The Time parser mishandles invalid URLs that have specific characters. It causes an increase in execution time for parsing strings to Time objects. The fixed versions are 0.1.1 and 0.2.2.
medium 5.3
A ReDoS issue was discovered in the URI component through 0.12.0 in Ruby through 3.2.1. The URI parser mishandles invalid URLs that have specific characters. It causes an increase in execution time for parsing strings to URI objects. The fixed versions are 0.12.1, 0.11.1, 0.10.2 and 0.10.0.1.
medium 5.3
Osprey Pump Controller version 1.01 is vulnerable an unauthenticated OS command injection vulnerability. This can be exploited to inject and execute arbitrary shell commands through a HTTP GET parameter called by DataLogView.php, EventsView.php and AlarmsView.php scripts.
critical 9.8
A vulnerability exists in the SDM600 file permission validation. An attacker could exploit the vulnerability by gaining access to the system and uploading a specially crafted message to the system node, which could result in Arbitrary code Executing. This issue affects: All SDM600 versions prior to version 1.2 FP3 HF4 (Build Nr. 1.2.23000.291) List of CPEs: * cpe:2.3:a:hitachienergy:sdm600:1.0:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.1:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.9002.257:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.10002.257:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.11002.149:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.12002.222:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.13002.72:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.44:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.92:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.108:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.182:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.257:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.342:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.447:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.481:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.506:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.566:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.20000.3174:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.21000.291:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.21000.931:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.21000.105:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.23000.291:*:*:*:*:*:*:*
critical 9.9
The listed versions of AVEVA Plant SCADA and AVEVA Telemetry Server are vulnerable to an improper authorization exploit which could allow an unauthenticated user to remotely read data, cause denial of service, and tamper with alarm states.
critical 9.8
Use-after-free vulnerability exists in Kostac PLC Programming Software (Former name: Koyo PLC Programming Software) Version 1.6.9.0 and earlier. With the abnormal value given as the maximum number of columns for the PLC program, the process accesses the freed memory. As a result, opening a specially crafted project file may lead to information disclosure and/or arbitrary code execution.
high 7.8
Out-of-bounds read vulnerability exists in Kostac PLC Programming Software (Former name: Koyo PLC Programming Software) Version 1.6.9.0 and earlier. The insufficient buffer size for the PLC program instructions leads to out-of-bounds read. As a result, opening a specially crafted project file may lead to information disclosure and/or arbitrary code execution.
high 7.8
Out-of-bounds read vulnerability exists in Kostac PLC Programming Software (Former name: Koyo PLC Programming Software) Version 1.6.9.0 and earlier. When processing a comment block in stage information, the end of data cannot be verified and out-of-bounds read occurs. As a result, opening a specially crafted project file may lead to information disclosure and/or arbitrary code execution.
high 7.8
Korenix JetWave 4200 Series 1.3.0 and JetWave 3200 Series 1.6.0 are vulnerable to Denial of Service via /goform/formDefault.
medium 6.5
Korenix JetWave 4200 Series 1.3.0 and JetWave 3000 Series 1.6.0 are vulnerable to Command Injection. An attacker can modify the file_name parameter to execute commands as root.
high 8.8
Korenix Jetwave 4200 Series 1.3.0 and JetWave 3000 Series 1.6.0 are vulnerable to Command Injection via /goform/formSysCmd. An attacker an modify the sysCmd parameter in order to execute commands as root.
high 8.8
In multiple products by Festo a remote unauthenticated attacker could use functions of an undocumented protocol which could lead to a complete loss of confidentiality, integrity and availability.
critical 9.8
Data Integrity Failure in 'Backup Config' in D-Link DNR-322L <= 2.60B15 allows an authenticated attacker to execute OS level commands on the device.
high 8.8
An Improper Input Validation vulnerability exists in Trihedral VTScada version 12.0.38 and prior. A specifically malformed HTTP request could cause the affected VTScada to crash. Both local area network (LAN)-only and internet facing systems are affected.
high 7.5
A CWE-640: Weak Password Recovery Mechanism for Forgotten Password vulnerability exists that could cause unauthorized access in read and write mode to the controller when communicating over Modbus. Affected Products: EcoStruxure Control Expert Including all Unity Pro versions (former name of EcoStruxure Control Expert) (V15.0 SP1 and prior), EcoStruxure Process Expert, Including all versions of EcoStruxure Hybrid DCS (former name of EcoStruxure Process Expert) (V2021 and prior), Modicon M340 CPU (part numbers BMXP34*) (V3.40 and prior), Modicon M580 CPU (part numbers BMEP* and BMEH*) (V3.20 and prior).
critical 9.8
Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x stores the password in plaintext in a file that is in the same directory as the executable file. ISaGRAF Runtime reads the file and saves the data in a variable without any additional modification. A local, unauthenticated attacker could compromise the user passwords, resulting in information disclosure.
high 7.8
Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x searches for and loads DLLs as dynamic libraries. Uncontrolled loading of dynamic libraries could allow a local, unauthenticated attacker to execute arbitrary code. This vulnerability only affects ISaGRAF Runtime when running on Microsoft Windows systems.
medium 6.7
Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x includes the functionality of setting a password that is required to execute privileged commands. The password value passed to ISaGRAF Runtime is the result of encryption performed with a fixed key value using the tiny encryption algorithm (TEA) on an entered or saved password. A remote, unauthenticated attacker could pass their own encrypted password to the ISaGRAF 5 Runtime, which may result in information disclosure on the device.
medium 5.3
On ICL ScadaFlex II SCADA Controller SC-1 and SC-2 1.03.07 devices, unauthenticated remote attackers can overwrite, delete, or create files.
critical 9.1
Exploitation of this vulnerability may result in local privilege escalation and code execution. GE maintains exploitation of this vulnerability is only possible if the attacker has login access to a machine actively running CIMPLICITY, the CIMPLICITY server is not already running a project, and the server is licensed for multiple projects.
high 7.5
The affected product is vulnerable due to cleartext transmission of credentials seen in the CIMPLICITY network, which can be easily spoofed and used to log in to make operational changes to the system.
high 7.5
A CWE-665: Improper Initialization vulnerability exists that could cause information exposure when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)
high 7.5
Buffer Over-read vulnerability in Mitsubishi Electric MC Works64 versions 4.00A to 4.04E, Mitsubishi Electric GENESIS64 versions 10.97 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 and prior, Mitsubishi Electric ICONICS Suite versions 10.97 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 and prior, Mitsubishi Electric GENESIS32 versions 9.7 and prior, and Mitsubishi Electric Iconics Digital Solutions GENESIS32 versions 9.7 and prior allows an attacker to cause a DoS condition in the database server by getting a legitimate user to import a configuration file containing specially crafted stored procedures into GENESIS64, ICONICS Suite, MC Works64, or GENESIS32 and execute commands against the database from GENESIS64, ICONICS Suite, MC Works64, or GENESIS32.
medium 5.9
Plaintext Storage of a Password vulnerability in Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior and ICONICS GENESIS64 versions 10.90 to 10.97 allows a local authenticated attacker to gain authentication information and to access the database illegally. This is because when configuration information of GridWorX, a database linkage function of GENESIS64 and MC Works64, is exported to a CSV file, the authentication information is saved in plaintext, and an attacker who can access this CSV file can gain the authentication information.
medium 5.5
Incomplete List of Disallowed Inputs vulnerability in Mitsubishi Electric MC Works64 versions 4.00A (10.95.201.23) to 4.04E (10.95.210.01), ICONICS GENESIS64 versions 10.95.3 to 10.97, ICONICS Hyper Historian versions 10.95.3 to 10.97, ICONICS AnalytiX versions 10.95.3 to 10.97 and ICONICS MobileHMI versions 10.95.3 to 10.97 allows a remote unauthenticated attacker to bypass the authentication of MC Works64, GENESIS64, Hyper Historian, AnalytiX and MobileHMI, and gain unauthorized access to the products, by sending specially crafted WebSocket packets to FrameWorX server, one of the functions of the products.
critical 9.8
Cross-site Scripting vulnerability in Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior and ICONICS MobileHMI versions 10.96.2 and prior allows a remote unauthenticated attacker to gain authentication information of an MC Works64 or MobileHMI and perform any operation using the acquired authentication information, by injecting a malicious script in the URL of a monitoring screen delivered from the MC Works64 server or MobileHMI server to an application for mobile devices and leading a legitimate user to access this URL.
medium 6.1
PLC Editor Versions 1.3.8 and prior is vulnerable to an out-of-bounds write while processing project files, which may allow an attacker to execute arbitrary code.
high 7.8
Delta Electronic DOPSoft 2 (Version 2.00.07 and prior) lacks proper validation of user-supplied data when parsing specific project files. This could result in multiple out-of-bounds write instances. An attacker could leverage this vulnerability to execute code in the context of the current process.
high 7.8
OpenPLC ScadaBR through 0.9.1 on Linux and through 1.12.4 on Windows allows stored XSS via system_settings.shtm.
medium 5.4
OpenPLC ScadaBR through 0.9.1 on Linux and through 1.12.4 on Windows allows remote authenticated users to upload and execute arbitrary JSP files via view_edit.shtm.
high 8.8
The WADashboard component of WebAccess/SCADA Versions 9.0 and prior may allow an attacker to control or influence a path used in an operation on the filesystem and remotely execute code as an administrator.
high 8.8
WECON PLC Editor Versions 1.3.8 and prior has a heap-based buffer overflow vulnerabilities have been identified that may allow arbitrary code execution.
high 8.8
WECON PLC Editor Versions 1.3.8 and prior has a stack-based buffer overflow vulnerability has been identified that may allow arbitrary code execution.
high 8.8
499ES EtherNet/IP (ENIP) Adaptor Source Code is vulnerable to a stack-based buffer overflow, which may allow an attacker to send a specially crafted packet that may result in a denial-of-service condition or code execution.
critical 9.8
An SQL injection vulnerability exists in the CHaD.asmx web service functionality of eDNA Enterprise Data Historian 3.0.1.2/7.5.4989.33053. Specially crafted SOAP web requests can cause SQL injections resulting in data compromise. Parameter InstanceName in CHaD.asmx is vulnerable to unauthenticated SQL injection attacks.
critical 9.8
SQL injection vulnerability exists in the CHaD.asmx web service functionality of eDNA Enterprise Data Historian 3.0.1.2/7.5.4989.33053. Specially crafted SOAP web requests can cause SQL injections resulting in data compromise. Parameter ClassName in CHaD.asmx is vulnerable to unauthenticated SQL injection attacks.
critical 9.8
An SQL injection vulnerability exists in the CHaD.asmx web service functionality of eDNA Enterprise Data Historian 3.0.1.2/7.5.4989.33053. Specially crafted SOAP web requests can cause SQL injections resulting in data compromise. Parameter InstancePath in CHaD.asmx is vulnerable to unauthenticated SQL injection attacks.
critical 9.8
An issue was discovered on D-Link DCS-2530L before 1.06.01 Hotfix and DCS-2670L through 2.02 devices. cgi-bin/ddns_enc.cgi allows authenticated command injection.
high 8.8
An issue was discovered on D-Link DCS-2530L before 1.06.01 Hotfix and DCS-2670L through 2.02 devices. The unauthenticated /config/getuser endpoint allows for remote administrator password disclosure.
high 7.5
Rapid Software LLC Rapid SCADA 5.8.0 is affected by a local privilege escalation vulnerability in the ScadaAgentSvc.exe executable file. An attacker can obtain admin privileges by placing a malicious .exe file in the application and renaming it ScadaAgentSvc.exe, which would result in executing the binary as NT AUTHORITY\SYSTEM in a Windows operating system. For example, an attacker can plant a reverse shell from a low privileged user account and by restarting the computer, the malicious service will be started as NT AUTHORITY\SYSTEM by giving the attacker full system access to the remote PC.
high 7.8
AsrDrv103.sys in the ASRock RGB Driver does not properly restrict access from user space, as demonstrated by triggering a triple fault via a request to zero CR3.
medium 5.5
Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers cause a denial-of-service condition due to a lack of proper validation of the length of user-supplied data, prior to copying it to a fixed-length stack-based buffer. Authentication is not required to exploit this vulnerability.
high 7.5
Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers to execute arbitrary code due to the lack of proper validation of user-supplied data, which can result in a type confusion condition. Authentication is not required to exploit this vulnerability. Only applicable to installations using DNP3 Data Sets.
critical 9.8
A CWE-306: Missing Authentication for Critical Function vulnerability exists in IGSS (Versions 14 and prior using the service: IGSSupdate), which could allow a local user to execute processes that otherwise require escalation privileges when sending local network commands to the IGSS Update Service.
high 7.8