OT vulnerabilities
Showing 451 - 500 of 501 CVEs
- CVE-2021-44228 Published Dec 10, 2021
Apache Log4j2 2.0-beta9 through 2.15.0 (excluding security releases 2.12.2, 2.12.3, and 2.3.1) JNDI features used in configuration, log messages, and parameters do not protect against attacker controlled LDAP and other JNDI related endpoints. An attacker who can control log messages or log message parameters can execute arbitrary code loaded from LDAP servers when message lookup substitution is enabled. From log4j 2.15.0, this behavior has been disabled by default. From version 2.16.0 (along with 2.12.2, 2.12.3, and 2.3.1), this functionality has been completely removed. Note that this vulnerability is specific to log4j-core and does not affect log4net, log4cxx, or other Apache Logging Services projects.
- CVE-2021-23758 Published Dec 3, 2021
All versions of package ajaxpro.2 are vulnerable to Deserialization of Untrusted Data due to the possibility of deserialization of arbitrary .NET classes, which can be abused to gain remote code execution.
- CVE-2021-34563 Published Aug 31, 2021
In PEPPERL+FUCHS WirelessHART-Gateway 3.0.8 and 3.0.9 the HttpOnly attribute is not set on a cookie. This allows the cookie's value to be read or set by client-side JavaScript.
- CVE-2020-35683 Published Aug 19, 2021
An issue was discovered in HCC Nichestack 3.0. The code that parses ICMP packets relies on an unchecked value of the IP payload size (extracted from the IP header) to compute the ICMP checksum. When the IP payload size is set to be smaller than the size of the IP header, the ICMP checksum computation function may read out of bounds, causing a Denial-of-Service.
- CVE-2021-22937 Published Aug 16, 2021
A vulnerability in Pulse Connect Secure before 9.1R12 could allow an authenticated administrator to perform a file write via a maliciously crafted archive uploaded in the administrator web interface.
- CVE-2021-31630 Published Aug 3, 2021
Command Injection in Open PLC Webserver v3 allows remote attackers to execute arbitrary code via the "Hardware Layer Code Box" component on the "/hardware" page of the application.
- CVE-2021-26829 Published Jun 11, 2021
OpenPLC ScadaBR through 0.9.1 on Linux and through 1.12.4 on Windows allows stored XSS via system_settings.shtm.
- CVE-2021-26828 Published Jun 11, 2021
OpenPLC ScadaBR through 0.9.1 on Linux and through 1.12.4 on Windows allows remote authenticated users to upload and execute arbitrary JSP files via view_edit.shtm.
- CVE-2021-22900 Published May 27, 2021
A vulnerability allowed multiple unrestricted uploads in Pulse Connect Secure before 9.1R11.4 that could lead to an authenticated administrator to perform a file write via a maliciously crafted archive upload in the administrator web interface.
- CVE-2021-22899 Published May 27, 2021
A command injection vulnerability exists in Pulse Connect Secure before 9.1R11.4 allows a remote authenticated attacker to perform remote code execution via Windows Resource Profiles Feature
- CVE-2021-22894 Published May 27, 2021
A buffer overflow vulnerability exists in Pulse Connect Secure before 9.1R11.4 allows a remote authenticated attacker to execute arbitrary code as the root user via maliciously crafted meeting room.
- CVE-2021-22893 Published Apr 23, 2021
Pulse Connect Secure 9.0R3/9.1R1 and higher is vulnerable to an authentication bypass vulnerability exposed by the Windows File Share Browser and Pulse Secure Collaboration features of Pulse Connect Secure that can allow an unauthenticated user to perform remote arbitrary code execution on the Pulse Connect Secure gateway. This vulnerability has been exploited in the wild.
- CVE-2020-26997 Published Apr 22, 2021
A vulnerability has been identified in Solid Edge SE2020 (All versions < SE2020MP13), Solid Edge SE2020 (All versions < SE2020MP14), Solid Edge SE2021 (All Versions < SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could lead to pointer dereferences of a value obtained from untrusted source. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-11919)
- CVE-2020-14516 Published Mar 18, 2021
In Rockwell Automation FactoryTalk Services Platform Versions 6.10.00 and 6.11.00, there is an issue with the implementation of the SHA-256 hashing algorithm with FactoryTalk Services Platform that prevents the user password from being hashed properly.
- CVE-2021-22681 Published Mar 3, 2021
Rockwell Automation Studio 5000 Logix Designer Versions 21 and later, and RSLogix 5000 Versions 16 through 20 use a key to verify Logix controllers are communicating with Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800. Rockwell Automation Studio 5000 Logix Designer Versions 21 and later and RSLogix 5000: Versions 16 through 20 are vulnerable because an unauthenticated attacker could bypass this verification mechanism and authenticate with Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800.
- CVE-2020-10048 Published Feb 9, 2021
A vulnerability has been identified in SIMATIC PCS 7 (All versions), SIMATIC WinCC (All versions < V7.5 SP2). Due to an insecure password verification process, an attacker could bypass the password protection set on protected files, thus being granted access to the protected content, circumventing authentication.
- CVE-2020-28895 Published Feb 3, 2021
In Wind River VxWorks, memory allocator has a possible overflow in calculating the memory block's size to be allocated by calloc(). As a result, the actual memory allocated is smaller than the buffer size specified by the arguments, leading to memory corruption.
- CVE-2021-22697 Published Jan 26, 2021
A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists in the EcoStruxure Power Build - Rapsody software (V2.1.13 and prior) that could allow a use-after-free condition which could result in remote code execution when a malicious SSD file is uploaded and improperly parsed.
- CVE-2020-28391 Published Jan 12, 2021
A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-200RNA switch family (All versions < V3.2.7). Devices create a new unique key upon factory reset, except when used with C-PLUG. When used with C-PLUG the devices use the hardcoded private RSA-key shipped with the firmware-image. An attacker could leverage this situation to a man-in-the-middle situation and decrypt previously captured traffic.
- CVE-2020-26995 Published Jan 12, 2021
A vulnerability has been identified in JT2Go (All versions < V13.1.0), Teamcenter Visualization (All versions < V13.1.0). Affected applications lack proper validation of user-supplied data when parsing of SGI and RGB files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-11992)
- CVE-2020-13573 Published Jan 7, 2021
A denial-of-service vulnerability exists in the Ethernet/IP server functionality of Rockwell Automation RSLinx Classic 2.57.00.14 CPR 9 SR 3. A specially crafted network request can lead to a denial of service. An attacker can send a sequence of malicious packets to trigger this vulnerability.
- CVE-2020-5801 Published Dec 29, 2020
An attacker can craft and send an OpenNamespace message to port 4241 with valid session-id that triggers an unhandled exception in CFTLDManager::HandleRequest function in RnaDaSvr.dll, resulting in process termination. Observed in FactoryTalk Linx 6.11. All versions of FactoryTalk Linx are affected.
- CVE-2020-8260 Published Oct 28, 2020
A vulnerability in the Pulse Connect Secure < 9.1R9 admin web interface could allow an authenticated attacker to perform an arbitrary code execution using uncontrolled gzip extraction.
- CVE-2020-14883 Published Oct 21, 2020
Vulnerability in the Oracle WebLogic Server product of Oracle Fusion Middleware (component: Console). Supported versions that are affected are 10.3.6.0.0, 12.1.3.0.0, 12.2.1.3.0, 12.2.1.4.0 and 14.1.1.0.0. Easily exploitable vulnerability allows high privileged attacker with network access via HTTP to compromise Oracle WebLogic Server. Successful attacks of this vulnerability can result in takeover of Oracle WebLogic Server. CVSS 3.1 Base Score 7.2 (Confidentiality, Integrity and Availability impacts). CVSS Vector: (CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H).
- CVE-2020-14882 Published Oct 21, 2020
Vulnerability in the Oracle WebLogic Server product of Oracle Fusion Middleware (component: Console). Supported versions that are affected are 10.3.6.0.0, 12.1.3.0.0, 12.2.1.3.0, 12.2.1.4.0 and 14.1.1.0.0. Easily exploitable vulnerability allows unauthenticated attacker with network access via HTTP to compromise Oracle WebLogic Server. Successful attacks of this vulnerability can result in takeover of Oracle WebLogic Server. CVSS 3.1 Base Score 9.8 (Confidentiality, Integrity and Availability impacts). CVSS Vector: (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).
- CVE-2020-8243 Published Sep 30, 2020
A vulnerability in the Pulse Connect Secure < 9.1R8.2 admin web interface could allow an authenticated attacker to upload custom template to perform an arbitrary code execution.
- CVE-2020-16233 Published Sep 16, 2020
An attacker could send a specially crafted packet that could have CodeMeter (All versions prior to 7.10) send back packets containing data from the heap.
- CVE-2020-15483 Published Aug 26, 2020
An issue was discovered on Nescomed Multipara Monitor M1000 devices. The physical UART debug port provides a shell, without requiring a password, with complete access.
- CVE-2020-14520 Published Jul 31, 2020
The affected product is vulnerable to an information leak, which may allow an attacker to obtain sensitive information on the Ignition 8 (all versions prior to 8.0.13).
- CVE-2020-12029 Published Jul 20, 2020
All versions of FactoryTalk View SE do not properly validate input of filenames within a project directory. A remote, unauthenticated attacker may be able to execute a crafted file on a remote endpoint that may result in remote code execution (RCE). Rockwell Automation recommends applying patch 1126289. Before installing this patch, the patch rollup dated 06 Apr 2020 or later MUST be applied. 1066644 – Patch Roll-up for CPR9 SRx.
- CVE-2020-15368 Published Jun 29, 2020
AsrDrv103.sys in the ASRock RGB Driver does not properly restrict access from user space, as demonstrated by triggering a triple fault via a request to zero CR3.
- CVE-2020-12021 Published Jun 23, 2020
In OSIsoft PI Web API 2019 Patch 1 (1.12.0.6346) and all previous versions, the affected product is vulnerable to a cross-site scripting attack, which may allow an attacker to remotely execute arbitrary code.
- CVE-2020-11910 Published Jun 17, 2020
The Treck TCP/IP stack before 6.0.1.66 has an ICMPv4 Out-of-bounds Read.
- CVE-2020-11900 Published Jun 17, 2020
The Treck TCP/IP stack before 6.0.1.41 has an IPv4 tunneling Double Free.
- CVE-2020-11899 Published Jun 17, 2020
The Treck TCP/IP stack before 6.0.1.66 has an IPv6 Out-of-bounds Read.
- CVE-2020-2026 Published Jun 10, 2020
A malicious guest compromised before a container creation (e.g. a malicious guest image or a guest running multiple containers) can trick the kata runtime into mounting the untrusted container filesystem on any host path, potentially allowing for code execution on the host. This issue affects: Kata Containers 1.11 versions earlier than 1.11.1; Kata Containers 1.10 versions earlier than 1.10.5; Kata Containers 1.9 and earlier versions.
- CVE-2020-10616 Published May 14, 2020
Opto 22 SoftPAC Project Version 9.6 and prior. SoftPAC does not specify the path of multiple imported .dll files. Therefore, an attacker can replace them and execute code whenever the service starts.
- CVE-2020-10618 Published May 4, 2020
LCDS LAquis SCADA Versions 4.3.1 and prior. The affected product is vulnerable to sensitive information exposure by unauthorized users.
- CVE-2020-6996 Published Apr 15, 2020
Triangle MicroWorks DNP3 Outstation LibrariesDNP3 Outstation .NET Protocol components and DNP3 Outstation ANSI C source code libraries are affected:3.16.00 through 3.25.01. A specially crafted message may cause a stack-based buffer overflow. Authentication is not required to exploit this vulnerability.
- CVE-2020-10615 Published Apr 15, 2020
Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers cause a denial-of-service condition due to a lack of proper validation of the length of user-supplied data, prior to copying it to a fixed-length stack-based buffer. Authentication is not required to exploit this vulnerability.
- CVE-2020-10613 Published Apr 15, 2020
Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers to disclose sensitive information due to the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated structure. Authentication is not required to exploit this vulnerability. Only applicable to installations using DNP3 Data Sets.
- CVE-2020-10611 Published Apr 15, 2020
Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers to execute arbitrary code due to the lack of proper validation of user-supplied data, which can result in a type confusion condition. Authentication is not required to exploit this vulnerability. Only applicable to installations using DNP3 Data Sets.
- CVE-2020-6992 Published Apr 15, 2020
A local privilege escalation vulnerability has been identified in the GE Digital CIMPLICITY HMI/SCADA product v10.0 and prior. If exploited, this vulnerability could allow an adversary to modify the system, leading to the arbitrary execution of code. This vulnerability is only exploitable if an attacker has access to an authenticated session. GE Digital CIMPLICITY v11.0, released January 2020, contains mitigation for this local privilege escalation vulnerability. GE Digital recommends all users upgrade to GE CIMPLICITY v11.0 or newer.
- CVE-2020-10631 Published Apr 9, 2020
An attacker could use a specially crafted URL to delete or read files outside the WebAccess/NMS's (versions prior to 3.0.2) control.
- CVE-2020-10623 Published Apr 9, 2020
Multiple vulnerabilities could allow an attacker with low privileges to perform SQL injection on WebAccess/NMS (versions prior to 3.0.2) to gain access to sensitive information.
- CVE-2020-10619 Published Apr 9, 2020
An attacker could use a specially crafted URL to delete files outside the WebAccess/NMS's (versions prior to 3.0.2) control.
- CVE-2020-10617 Published Apr 9, 2020
There are multiple ways an unauthenticated attacker could perform SQL injection on WebAccess/NMS (versions prior to 3.0.2) to gain access to sensitive information.
- CVE-2020-10603 Published Apr 9, 2020
WebAccess/NMS (versions prior to 3.0.2) does not properly sanitize user input and may allow an attacker to inject system commands remotely.
- CVE-2020-10621 Published Apr 9, 2020
Multiple issues exist that allow files to be uploaded and executed on the WebAccess/NMS (versions prior to 3.0.2).
- CVE-2020-6974 Published Apr 7, 2020
Honeywell Notifier Web Server (NWS) Version 3.50 is vulnerable to a path traversal attack, which allows an attacker to bypass access to restricted directories. Honeywell has released a firmware update to address the problem.
Apache Log4j2 2.0-beta9 through 2.15.0 (excluding security releases 2.12.2, 2.12.3, and 2.3.1) JNDI features used in configuration, log messages, and parameters do not protect against attacker controlled LDAP and other JNDI related endpoints. An attacker who can control log messages or log message parameters can execute arbitrary code loaded from LDAP servers when message lookup substitution is enabled. From log4j 2.15.0, this behavior has been disabled by default. From version 2.16.0 (along with 2.12.2, 2.12.3, and 2.3.1), this functionality has been completely removed. Note that this vulnerability is specific to log4j-core and does not affect log4net, log4cxx, or other Apache Logging Services projects.
critical 10.0
All versions of package ajaxpro.2 are vulnerable to Deserialization of Untrusted Data due to the possibility of deserialization of arbitrary .NET classes, which can be abused to gain remote code execution.
high 8.1
In PEPPERL+FUCHS WirelessHART-Gateway 3.0.8 and 3.0.9 the HttpOnly attribute is not set on a cookie. This allows the cookie's value to be read or set by client-side JavaScript.
low 3.3
An issue was discovered in HCC Nichestack 3.0. The code that parses ICMP packets relies on an unchecked value of the IP payload size (extracted from the IP header) to compute the ICMP checksum. When the IP payload size is set to be smaller than the size of the IP header, the ICMP checksum computation function may read out of bounds, causing a Denial-of-Service.
high 7.5
A vulnerability in Pulse Connect Secure before 9.1R12 could allow an authenticated administrator to perform a file write via a maliciously crafted archive uploaded in the administrator web interface.
high 7.2
Command Injection in Open PLC Webserver v3 allows remote attackers to execute arbitrary code via the "Hardware Layer Code Box" component on the "/hardware" page of the application.
high 8.8
OpenPLC ScadaBR through 0.9.1 on Linux and through 1.12.4 on Windows allows stored XSS via system_settings.shtm.
medium 5.4
OpenPLC ScadaBR through 0.9.1 on Linux and through 1.12.4 on Windows allows remote authenticated users to upload and execute arbitrary JSP files via view_edit.shtm.
high 8.8
A vulnerability allowed multiple unrestricted uploads in Pulse Connect Secure before 9.1R11.4 that could lead to an authenticated administrator to perform a file write via a maliciously crafted archive upload in the administrator web interface.
high 7.2
A command injection vulnerability exists in Pulse Connect Secure before 9.1R11.4 allows a remote authenticated attacker to perform remote code execution via Windows Resource Profiles Feature
high 8.8
A buffer overflow vulnerability exists in Pulse Connect Secure before 9.1R11.4 allows a remote authenticated attacker to execute arbitrary code as the root user via maliciously crafted meeting room.
high 8.8
Pulse Connect Secure 9.0R3/9.1R1 and higher is vulnerable to an authentication bypass vulnerability exposed by the Windows File Share Browser and Pulse Secure Collaboration features of Pulse Connect Secure that can allow an unauthenticated user to perform remote arbitrary code execution on the Pulse Connect Secure gateway. This vulnerability has been exploited in the wild.
critical 10.0
A vulnerability has been identified in Solid Edge SE2020 (All versions < SE2020MP13), Solid Edge SE2020 (All versions < SE2020MP14), Solid Edge SE2021 (All Versions < SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could lead to pointer dereferences of a value obtained from untrusted source. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-11919)
high 7.8
In Rockwell Automation FactoryTalk Services Platform Versions 6.10.00 and 6.11.00, there is an issue with the implementation of the SHA-256 hashing algorithm with FactoryTalk Services Platform that prevents the user password from being hashed properly.
critical 10.0
Rockwell Automation Studio 5000 Logix Designer Versions 21 and later, and RSLogix 5000 Versions 16 through 20 use a key to verify Logix controllers are communicating with Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800. Rockwell Automation Studio 5000 Logix Designer Versions 21 and later and RSLogix 5000: Versions 16 through 20 are vulnerable because an unauthenticated attacker could bypass this verification mechanism and authenticate with Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800.
critical 9.8
A vulnerability has been identified in SIMATIC PCS 7 (All versions), SIMATIC WinCC (All versions < V7.5 SP2). Due to an insecure password verification process, an attacker could bypass the password protection set on protected files, thus being granted access to the protected content, circumventing authentication.
medium 5.5
In Wind River VxWorks, memory allocator has a possible overflow in calculating the memory block's size to be allocated by calloc(). As a result, the actual memory allocated is smaller than the buffer size specified by the arguments, leading to memory corruption.
high 7.3
A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists in the EcoStruxure Power Build - Rapsody software (V2.1.13 and prior) that could allow a use-after-free condition which could result in remote code execution when a malicious SSD file is uploaded and improperly parsed.
high 7.8
A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-200RNA switch family (All versions < V3.2.7). Devices create a new unique key upon factory reset, except when used with C-PLUG. When used with C-PLUG the devices use the hardcoded private RSA-key shipped with the firmware-image. An attacker could leverage this situation to a man-in-the-middle situation and decrypt previously captured traffic.
medium 5.9
A vulnerability has been identified in JT2Go (All versions < V13.1.0), Teamcenter Visualization (All versions < V13.1.0). Affected applications lack proper validation of user-supplied data when parsing of SGI and RGB files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-11992)
high 8.8
A denial-of-service vulnerability exists in the Ethernet/IP server functionality of Rockwell Automation RSLinx Classic 2.57.00.14 CPR 9 SR 3. A specially crafted network request can lead to a denial of service. An attacker can send a sequence of malicious packets to trigger this vulnerability.
high 7.5
An attacker can craft and send an OpenNamespace message to port 4241 with valid session-id that triggers an unhandled exception in CFTLDManager::HandleRequest function in RnaDaSvr.dll, resulting in process termination. Observed in FactoryTalk Linx 6.11. All versions of FactoryTalk Linx are affected.
high 7.5
A vulnerability in the Pulse Connect Secure < 9.1R9 admin web interface could allow an authenticated attacker to perform an arbitrary code execution using uncontrolled gzip extraction.
high 7.2
Vulnerability in the Oracle WebLogic Server product of Oracle Fusion Middleware (component: Console). Supported versions that are affected are 10.3.6.0.0, 12.1.3.0.0, 12.2.1.3.0, 12.2.1.4.0 and 14.1.1.0.0. Easily exploitable vulnerability allows high privileged attacker with network access via HTTP to compromise Oracle WebLogic Server. Successful attacks of this vulnerability can result in takeover of Oracle WebLogic Server. CVSS 3.1 Base Score 7.2 (Confidentiality, Integrity and Availability impacts). CVSS Vector: (CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H).
high 7.2
Vulnerability in the Oracle WebLogic Server product of Oracle Fusion Middleware (component: Console). Supported versions that are affected are 10.3.6.0.0, 12.1.3.0.0, 12.2.1.3.0, 12.2.1.4.0 and 14.1.1.0.0. Easily exploitable vulnerability allows unauthenticated attacker with network access via HTTP to compromise Oracle WebLogic Server. Successful attacks of this vulnerability can result in takeover of Oracle WebLogic Server. CVSS 3.1 Base Score 9.8 (Confidentiality, Integrity and Availability impacts). CVSS Vector: (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).
critical 9.8
A vulnerability in the Pulse Connect Secure < 9.1R8.2 admin web interface could allow an authenticated attacker to upload custom template to perform an arbitrary code execution.
high 7.2
An attacker could send a specially crafted packet that could have CodeMeter (All versions prior to 7.10) send back packets containing data from the heap.
high 7.5
An issue was discovered on Nescomed Multipara Monitor M1000 devices. The physical UART debug port provides a shell, without requiring a password, with complete access.
medium 6.8
The affected product is vulnerable to an information leak, which may allow an attacker to obtain sensitive information on the Ignition 8 (all versions prior to 8.0.13).
high 7.5
All versions of FactoryTalk View SE do not properly validate input of filenames within a project directory. A remote, unauthenticated attacker may be able to execute a crafted file on a remote endpoint that may result in remote code execution (RCE). Rockwell Automation recommends applying patch 1126289. Before installing this patch, the patch rollup dated 06 Apr 2020 or later MUST be applied. 1066644 – Patch Roll-up for CPR9 SRx.
critical 9.0
AsrDrv103.sys in the ASRock RGB Driver does not properly restrict access from user space, as demonstrated by triggering a triple fault via a request to zero CR3.
medium 5.5
In OSIsoft PI Web API 2019 Patch 1 (1.12.0.6346) and all previous versions, the affected product is vulnerable to a cross-site scripting attack, which may allow an attacker to remotely execute arbitrary code.
critical 9.0
The Treck TCP/IP stack before 6.0.1.66 has an ICMPv4 Out-of-bounds Read.
medium 5.3
The Treck TCP/IP stack before 6.0.1.41 has an IPv4 tunneling Double Free.
high 8.2
The Treck TCP/IP stack before 6.0.1.66 has an IPv6 Out-of-bounds Read.
medium 5.4
A malicious guest compromised before a container creation (e.g. a malicious guest image or a guest running multiple containers) can trick the kata runtime into mounting the untrusted container filesystem on any host path, potentially allowing for code execution on the host. This issue affects: Kata Containers 1.11 versions earlier than 1.11.1; Kata Containers 1.10 versions earlier than 1.10.5; Kata Containers 1.9 and earlier versions.
high 7.8
Opto 22 SoftPAC Project Version 9.6 and prior. SoftPAC does not specify the path of multiple imported .dll files. Therefore, an attacker can replace them and execute code whenever the service starts.
high 8.8
LCDS LAquis SCADA Versions 4.3.1 and prior. The affected product is vulnerable to sensitive information exposure by unauthorized users.
medium 5.5
Triangle MicroWorks DNP3 Outstation LibrariesDNP3 Outstation .NET Protocol components and DNP3 Outstation ANSI C source code libraries are affected:3.16.00 through 3.25.01. A specially crafted message may cause a stack-based buffer overflow. Authentication is not required to exploit this vulnerability.
critical 9.8
Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers cause a denial-of-service condition due to a lack of proper validation of the length of user-supplied data, prior to copying it to a fixed-length stack-based buffer. Authentication is not required to exploit this vulnerability.
high 7.5
Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers to disclose sensitive information due to the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated structure. Authentication is not required to exploit this vulnerability. Only applicable to installations using DNP3 Data Sets.
high 7.5
Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers to execute arbitrary code due to the lack of proper validation of user-supplied data, which can result in a type confusion condition. Authentication is not required to exploit this vulnerability. Only applicable to installations using DNP3 Data Sets.
critical 9.8
A local privilege escalation vulnerability has been identified in the GE Digital CIMPLICITY HMI/SCADA product v10.0 and prior. If exploited, this vulnerability could allow an adversary to modify the system, leading to the arbitrary execution of code. This vulnerability is only exploitable if an attacker has access to an authenticated session. GE Digital CIMPLICITY v11.0, released January 2020, contains mitigation for this local privilege escalation vulnerability. GE Digital recommends all users upgrade to GE CIMPLICITY v11.0 or newer.
medium 6.7
An attacker could use a specially crafted URL to delete or read files outside the WebAccess/NMS's (versions prior to 3.0.2) control.
critical 9.8
Multiple vulnerabilities could allow an attacker with low privileges to perform SQL injection on WebAccess/NMS (versions prior to 3.0.2) to gain access to sensitive information.
medium 6.5
An attacker could use a specially crafted URL to delete files outside the WebAccess/NMS's (versions prior to 3.0.2) control.
critical 9.1
There are multiple ways an unauthenticated attacker could perform SQL injection on WebAccess/NMS (versions prior to 3.0.2) to gain access to sensitive information.
high 7.5
WebAccess/NMS (versions prior to 3.0.2) does not properly sanitize user input and may allow an attacker to inject system commands remotely.
high 8.8
Multiple issues exist that allow files to be uploaded and executed on the WebAccess/NMS (versions prior to 3.0.2).
critical 9.8
Honeywell Notifier Web Server (NWS) Version 3.50 is vulnerable to a path traversal attack, which allows an attacker to bypass access to restricted directories. Honeywell has released a firmware update to address the problem.
critical 9.8