OT vulnerabilities
Showing 1 - 50 of 356 CVEs
- CVE-2026-9128 Published Jul 14, 2026
A code execution security issue exists within Studio 5000 Logix Designer® due to an unquoted search path in the External Tools configuration. The executable paths specified in the external tools configuration file are not properly quoted, and because these paths contain spaces, the operating system may resolve them to unintended executables placed earlier in the search order. If exploited, an attacker could plant a malicious executable in a location within the search path, resulting in arbitrary code execution with the same permissions of the user running the application.
- CVE-2026-9127 Published Jul 14, 2026
A remote code execution security issue exists within Studio 5000 Logix Designer® due to incorrect authorization on a configuration file. This can allow any authenticated user to modify the paths of external tools configured within the application. If exploited, an attacker could alter the configuration to point to a malicious executable, resulting in arbitrary code execution when any user interacts with the external tools functionality.
- CVE-2026-9108 Published Jul 14, 2026
A path traversal security issue exists within Studio 5000 Logix Designer® due to improper limitation of file paths within ACD project files. The software does not sanitize or validate file names embedded in the ACD file structure during the project opening procedure, allowing path traversal sequences to escape the intended extraction directory. If exploited, an attacker could craft a malicious ACD project file that results in arbitrary files being written to attacker-controlled locations on the file system, potentially leading to code execution.
- CVE-2026-10573 Published Jul 14, 2026
A denial-of-service security issue exists in 1734 POINT I/O™ module. The security issue stems from improper handling of crafted CIP messages, which can cause the module to enter a faulted state. A restart is required to recover.
- CVE-2026-56451 Published Jul 14, 2026
A vulnerability has been identified in Opcenter X (All versions < V2604). Affected applications do not properly validate the algorithm specified in the JSON Web Token (JWT) header. This could allow an unauthenticated remote attacker to forge arbitrary JWT, bypass authentication mechanisms and impersonate any user including administrative accounts, potentially gaining full unauthorized access to the application.
- CVE-2026-55726 Published Jul 3, 2026
The Azure Blob Storage container used for Gardyn device logs is publicly listable without authentication. A malicious user would be able to access any device log file available in the blob storage container.
- CVE-2026-54477 Published Jul 3, 2026
The admin panel lacks standard security headers, enabling clickjacking and cross-site scripting attacks.
- CVE-2026-13768 Published Jul 3, 2026
Gardyn devices expose a privileged iothubowner key. Access to this key will allow a malicious user to invoke an IoTHub Registry Manager function which returns connection information for all Gardyn Home Kit and Studio devices. Access to this key also allows a malicious user to execute arbitrary commands on a specific connected device and may allow the malicious user to pivot to other devices on the user's network.
- CVE-2026-56415 Published Jun 30, 2026
Storage Concentrator (SC & SCVM) contains a command injection vulnerability within the debug.pl script that is reachable without authentication. A remote attacker can submit a specially crafted HTTP request containing a malicious payload that is processed without adequate input sanitization, resulting in arbitrary command execution with root-level privileges on the underlying system.
- CVE-2026-56413 Published Jun 30, 2026
Storage Concentrator (SC & SCVM) contains a command injection vulnerability in the ms_service.pl service, which listens on TCP port 9000 by default and accepts custom network packets to perform device actions. An unauthenticated remote attacker can send a specially crafted packet containing a malicious payload that is processed without adequate sanitization, resulting in arbitrary command execution with root-level privileges.
- CVE-2026-55721 Published Jun 30, 2026
Storage Concentrator (SC & SCVM) is vulnerable to SQL injection through cookie values processed by the login.pl and debug.pl scripts. The cookie value is incorporated directly into database queries without adequate sanitization, allowing an unauthenticated remote attacker to manipulate those queries and extract sensitive information from the underlying database, including session tokens, password hashes, and stored secret keys.
- CVE-2026-50110 Published Jun 30, 2026
Storage Concentrator (SC & SCVM) contains hardcoded credentials for numerous internal services embedded within a configuration file. While the credentials are stored in an encoded format, the encoding can be reversed to plaintext. The exposed credentials span a broad range of internal services, including database accounts, licensing, replication services, and third-party integrations, meaning successful exploitation of this vulnerability could provide an attacker with unauthorized access to multiple interconnected systems.
- CVE-2026-50040 Published Jun 30, 2026
Storage Concentrator (SC & SCVM) is vulnerable to reflected cross-site scripting due to unsanitized content being echoed back in 404 error pages. An attacker can craft a malicious URL that, when visited by an authenticated user, causes arbitrary script content to execute within the victim's browser session in the context of the application. This could be leveraged to steal session cookies, redirect users, or perform unauthorized actions on behalf of the victim.
- CVE-2026-10763 Published Jun 30, 2026
PROMOD V is using insecure HTTP communication instead of HTTPS. The vulnerability is due to the lack of HTTPS support from 3rd party Digipede server.
- CVE-2026-54479 Published Jun 25, 2026
The WebSocket backend uses charging station identifiers to uniquely associate sessions but allows multiple endpoints to connect using the same session identifier. This implementation results in predictable session identifiers. This vulnerability may allow unauthorized users to authenticate as other users or enable a malicious actor to cause a denial-of-service condition by overwhelming the backend with valid session requests.
- CVE-2026-44622 Published Jun 25, 2026
Charging station authentication identifiers are publicly accessible via web-based mapping platforms.
- CVE-2026-50176 Published Jun 25, 2026
The WebSocket Application Programming Interface lacks restrictions on the number of authentication requests. This absence of rate limiting may allow an attacker to conduct denial-of-service attacks or brute-force attacks to gain unauthorized access.
- CVE-2026-40702 Published Jun 25, 2026
WebSocket endpoints lack proper authentication mechanisms, enabling attackers to impersonate charging stations. As a result, attackers can exploit this weakness to gain unauthorized access to sensitive data or perform unauthorized actions. Given that no authentication is required, this can lead to privilege escalation and potentially compromise the security of the entire system.
- CVE-2026-9717 Published Jun 25, 2026
CWE-78 Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could allow unauthorized execution of commands with elevated privileges, impacting system integrity, confidentiality, and availability when a privileged authenticated user interacts with a vulnerable network-exposed service.
- CVE-2026-9716 Published Jun 25, 2026
CWE-476 NULL Pointer Dereference vulnerability exists that could cause a denial-of-service condition, rendering the device’s HMI and configuration functionality unavailable when malformed requests are received over exposed network interfaces.
- CVE-2026-9650 Published Jun 25, 2026
CWE-522 Insufficiently Protected Credentials vulnerability that could cause unauthorized access and exposure of sensitive information when unauthenticated attacker accesses credentials stored within firmware or system files. With this credential an attacker could subsequently compromise the device if they have physical access to the device.
- CVE-2026-12104 Published Jun 19, 2026
OS command injection in the environment and tunnel configuration functionality in SIMA GmbH Bondix through version 1.25.7.5 on Linux allows an authenticated attacker with configuration write access to execute arbitrary operating-system commands via crafted configuration values passed to server-side scripts.
- CVE-2026-12569 Published Jun 18, 2026
A critical remote code execution (RCE) vulnerability has been reported in PTC Windchill PDMlink and PTC FlexPLM. The vulnerability may be exploited through the deserialization of untrusted data. * This advisory also applies to all CPS versions * The identified vulnerability also impacts Windchill and FlexPLM releases prior to 11.0 M030
- CVE-2026-48558 Published Jun 12, 2026
SimpleHelp versions 5.5.15 and prior and 6.0 pre-release versions contain an authentication bypass vulnerability in the OIDC authentication flow. When OIDC authentication is configured, identity tokens submitted during login are accepted without verifying their cryptographic signature. In a vulnerable configuration, a remote, unauthenticated attacker can submit a forged token containing arbitrary identity claims to obtain a fully authenticated technician session. In some configurations, this may also allow bypass of multi-factor authentication. No user interaction is required.
- CVE-2025-48595 Published Jun 1, 2026
In multiple locations, there is a possible way to achieve code execution due to an integer overflow. This could lead to local escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation.
- CVE-2026-8326 Published May 29, 2026
Path traversal vulnerability in Remote Spark (https://www.Remotespark.Com/) SparkView allows reading and writing arbitrary files in all directories as root. This leads to RCE. The affected component is the RDP drive redirection. Depending on implementation, the vulnerability can be exploited by an unauthenticated attacker. This issue affects SparkView: before build 1127.
- CVE-2026-9039 Published May 28, 2026
A configuration weakness in the device’s remote management service allows an authenticated session to be established over a communication channel intended solely for vehicle-charger signaling. The service is accessible on interfaces exposed through the charging connector, and it accepts a default administrative credential. A malicious device physically connected to the charging interface could leverage this misconfiguration to obtain full administrative access.
- CVE-2026-48027 Published May 27, 2026
Nx Console is the user interface for Nx & Lerna. On 19 May 2026, a malicious version of Nx Console, 18.95.0, was published at 12:30 PM UTC and removed soon after at 12:48 PM UTC, leaving it available for ~18 minutes in Visual Studio Marketplace. For OpenVSX, the problem was detected later, and the compromised version was available from 12:33 UTC to 13:09 UTC (~36 minutes). Version 18.100.0 of Nx Console is not compromised and users may remediate by upgrading to that version.
- CVE-2026-34910 Published May 22, 2026
A malicious actor with access to the network could exploit an Improper Input Validation vulnerability found in UniFi OS devices to execute a Command Injection.
- CVE-2026-34909 Published May 22, 2026
A malicious actor with access to the network could exploit a Path Traversal vulnerability found in UniFi OS devices to access files on the underlying system that could be manipulated to access an underlying account.
- CVE-2026-34908 Published May 22, 2026
A malicious actor with access to the network could exploit an Improper Access Control vulnerability found in UniFi OS devices to make unauthorized changes to the system.
- CVE-2026-41091 Published May 20, 2026
Improper link resolution before file access ('link following') in Microsoft Defender allows an authorized attacker to elevate privileges locally.
- CVE-2026-8605 Published May 19, 2026
In ScadaBR version 1.2.0, a Use of Hard-Coded Credentials vulnerability could allow an attacker to access the SCADA system as admin.
- CVE-2026-8604 Published May 19, 2026
In ScadaBR version 1.2.0, a CSRF vulnerability could allow an attacker to trigger any authenticated action through a victim's session by luring any logged-in user to a malicious webpage.
- CVE-2026-8603 Published May 19, 2026
In ScadaBR version 1.2.0, an OS Command Injection vulnerability could allow an attacker to execute commands as root on the SCADA system.
- CVE-2026-8602 Published May 19, 2026
In ScadaBR version 1.2.0, a Missing Authentication for Critical Function vulnerability could allow an unauthenticated attacker to send a HTTP GET requests to the SCADA system and inject arbitrary sensor readings.
- CVE-2026-8398 Published May 15, 2026
A supply chain attack compromised the official installation packages of DAEMON Tools Lite (Windows versions 12.5.0.2421 through 12.5.0.2434), distributed from the legitimate website daemon-tools.cc between approximately April 8, 2026, and May 5, 2026. Attackers gained unauthorized access to the vendor's (AVB Disc Soft) build or distribution infrastructure and trojanized three binaries: DTHelper.exe, DiscSoftBusServiceLite.exe, and DTShellHlp.exe. These files were digitally signed with the legitimate AVB Disc Soft code-signing certificate, allowing the malicious installers to appear trustworthy and bypass signature-based detection.
- CVE-2026-20182 Published May 14, 2026
May 2026: This security advisory provides the details and fix information for a vulnerability that was discovered and fixed after the was disclosed in February 2026. This new advisory is for a new vulnerability in the control connection handshaking. The section of this advisory includes Show Control Connections guidance to help with system checks. A vulnerability in the peering authentication in Cisco Catalyst SD-WAN Controller, formerly SD-WAN vSmart, Cisco Catalyst SD-WAN Manager, formerly SD-WAN vManage, and Cisco Catalyst SD-WAN Validator, formerly SD-WAN vBond, could allow an unauthenticated, remote attacker to bypass authentication and obtain administrative privileges on an affected system. This vulnerability exists because the peering authentication mechanism in an affected system is not working properly. An attacker could exploit this vulnerability by sending crafted requests to the affected system. A successful exploit could allow the attacker to log in to an affected Cisco Catalyst SD-WAN Controller as an internal, high-privileged, non-root user account. Using this account, the attacker could access NETCONF, which would then allow the attacker to manipulate network configuration for the SD-WAN fabric.
- CVE-2026-4827 Published May 12, 2026
CWE‑331: Insufficient Entropy vulnerability exists that could lead to unauthorized access when an attacker on the network can exploit weaknesses in session‑management protections.
- CVE-2026-45321 Published May 12, 2026
On 2026-05-11, between approximately 19:20 and 19:26 UTC, 84 malicious versions across 42 @tanstack/* packages were published to the npm registry. The publishes were authenticated via the legitimate GitHub Actions OIDC trusted-publisher binding for TanStack/router, but the publish workflow itself was not modified. The attacker chained three known vulnerability classes — a pull_request_target "Pwn Request" misconfiguration, GitHub Actions cache poisoning across the fork↔base trust boundary, and runtime memory extraction of the OIDC token from the Actions runner process — to publish credential-stealing malware under a trusted identity. Each affected package received exactly two malicious versions, published a few minutes apart.
- CVE-2026-8153 Published May 8, 2026
OS command injection in Dashboard Server interface in Universal Robots PolyScope versions prior to 5.25.1 allows unauthenticated attacker to craft commands that will execute code on the robot's OS.
- CVE-2026-20147 Published Apr 15, 2026
A vulnerability in Cisco ISE and Cisco ISE-PIC could allow an authenticated, remote attacker to execute arbitrary commands on the underlying operating system of an affected device. To exploit this vulnerability, the attacker must have valid administrative credentials. This vulnerability is due to insufficient validation of user-supplied input. An attacker could exploit this vulnerability by sending a crafted HTTP request to an affected device. A successful exploit could allow the attacker to obtain user-level access to the underlying operating system and then elevate privileges to root. In single-node ISE deployments, successful exploitation of this vulnerability could cause the affected ISE node to become unavailable, resulting in a denial of service (DoS) condition. In that condition, endpoints that have not already authenticated would be unable to access the network until the node is restored.
- CVE-2026-32201 Published Apr 14, 2026
Improper input validation in Microsoft Office SharePoint allows an unauthorized attacker to perform spoofing over a network.
- CVE-2026-33892 Published Apr 14, 2026
A vulnerability has been identified in Industrial Edge Management Pro V1 (All versions >= V1.7.6 < V1.15.17), Industrial Edge Management Pro V2 (All versions >= V2.0.0 < V2.1.1), Industrial Edge Management Virtual (All versions >= V2.2.0 < V2.8.0). Affected management systems do not properly enforce user authentication on remote connections to devices. This could facilitate an unauthenticated remote attacker to circumvent authentication and impersonate a legitimate user. Successful exploitation requires that the attacker has identified the header and port used for remote connections to devices and that the remote connection feature is enabled for the device. Exploitation allows the attacker to tunnel to the device. Security features on this device itself (e.g. app specific authentication) are not affected.
- CVE-2026-4436 Published Apr 9, 2026
A low-privileged remote attacker can send Modbus packets to manipulate register values that are inputs to the odorant injection logic such that too much or too little odorant is injected into a gas line.
- CVE-2026-35063 Published Apr 9, 2026
OpenPLC_V3 REST API endpoint checks for JWT presence but never verifies the caller's role. Any authenticated user with role=user can delete any other user, including administrators, by specifying their user ID or they can create new accounts with role=admin, escalating to full administrator access.
- CVE-2026-39337 Published Apr 7, 2026
ChurchCRM is an open-source church management system. Prior to 7.1.0, critical pre-authentication remote code execution vulnerability in ChurchCRM's setup wizard allows unauthenticated attackers to inject arbitrary PHP code during the initial installation process, leading to complete server compromise. The "$dbPassword" variable is not sanitized. This vulnerability exists due to an incomplete fix for CVE-2025-62521. This vulnerability is fixed in 7.1.0.
- CVE-2026-34208 Published Apr 6, 2026
SandboxJS is a JavaScript sandboxing library. Prior to 0.8.36, SandboxJS blocks direct assignment to global objects (for example Math.random = ...), but this protection can be bypassed through an exposed callable constructor path: this.constructor.call(target, attackerObject). Because this.constructor resolves to the internal SandboxGlobal function and Function.prototype.call is allowed, attacker code can write arbitrary properties into host global objects and persist those mutations across sandbox instances in the same process. This vulnerability is fixed in 0.8.36.
- CVE-2026-27447 Published Apr 3, 2026
OpenPrinting CUPS is an open source printing system for Linux and other Unix-like operating systems. In versions 2.4.16 and prior, CUPS daemon (cupsd) contains an authorization bypass vulnerability due to case-insensitive username comparison during authorization checks. The vulnerability allows an unprivileged user to gain unauthorized access to restricted operations by using a user with a username that differs only in case from an authorized user. At time of publication, there are no publicly available patches.
- CVE-2026-4433 Published Mar 24, 2026
An SSH misconfigurations exists in Tenable OT that led to the potential exfiltration of socket, port, and service information via the ostunnel user and GatewayPorts. This could be used to potentially glean information about the underlying system and give an attacker information that could be used to attempt to compromise the host.
A code execution security issue exists within Studio 5000 Logix Designer® due to an unquoted search path in the External Tools configuration. The executable paths specified in the external tools configuration file are not properly quoted, and because these paths contain spaces, the operating system may resolve them to unintended executables placed earlier in the search order. If exploited, an attacker could plant a malicious executable in a location within the search path, resulting in arbitrary code execution with the same permissions of the user running the application.
high 7.3
A remote code execution security issue exists within Studio 5000 Logix Designer® due to incorrect authorization on a configuration file. This can allow any authenticated user to modify the paths of external tools configured within the application. If exploited, an attacker could alter the configuration to point to a malicious executable, resulting in arbitrary code execution when any user interacts with the external tools functionality.
high 7.3
A path traversal security issue exists within Studio 5000 Logix Designer® due to improper limitation of file paths within ACD project files. The software does not sanitize or validate file names embedded in the ACD file structure during the project opening procedure, allowing path traversal sequences to escape the intended extraction directory. If exploited, an attacker could craft a malicious ACD project file that results in arbitrary files being written to attacker-controlled locations on the file system, potentially leading to code execution.
medium 5.4
A denial-of-service security issue exists in 1734 POINT I/O™ module. The security issue stems from improper handling of crafted CIP messages, which can cause the module to enter a faulted state. A restart is required to recover.
high 8.7
A vulnerability has been identified in Opcenter X (All versions < V2604). Affected applications do not properly validate the algorithm specified in the JSON Web Token (JWT) header. This could allow an unauthenticated remote attacker to forge arbitrary JWT, bypass authentication mechanisms and impersonate any user including administrative accounts, potentially gaining full unauthorized access to the application.
critical 10.0
The Azure Blob Storage container used for Gardyn device logs is publicly listable without authentication. A malicious user would be able to access any device log file available in the blob storage container.
medium 6.9
The admin panel lacks standard security headers, enabling clickjacking and cross-site scripting attacks.
medium 5.1
Gardyn devices expose a privileged iothubowner key. Access to this key will allow a malicious user to invoke an IoTHub Registry Manager function which returns connection information for all Gardyn Home Kit and Studio devices. Access to this key also allows a malicious user to execute arbitrary commands on a specific connected device and may allow the malicious user to pivot to other devices on the user's network.
critical 9.5
Storage Concentrator (SC & SCVM) contains a command injection vulnerability within the debug.pl script that is reachable without authentication. A remote attacker can submit a specially crafted HTTP request containing a malicious payload that is processed without adequate input sanitization, resulting in arbitrary command execution with root-level privileges on the underlying system.
critical 10.0
Storage Concentrator (SC & SCVM) contains a command injection vulnerability in the ms_service.pl service, which listens on TCP port 9000 by default and accepts custom network packets to perform device actions. An unauthenticated remote attacker can send a specially crafted packet containing a malicious payload that is processed without adequate sanitization, resulting in arbitrary command execution with root-level privileges.
critical 10.0
Storage Concentrator (SC & SCVM) is vulnerable to SQL injection through cookie values processed by the login.pl and debug.pl scripts. The cookie value is incorporated directly into database queries without adequate sanitization, allowing an unauthenticated remote attacker to manipulate those queries and extract sensitive information from the underlying database, including session tokens, password hashes, and stored secret keys.
critical 9.2
Storage Concentrator (SC & SCVM) contains hardcoded credentials for numerous internal services embedded within a configuration file. While the credentials are stored in an encoded format, the encoding can be reversed to plaintext. The exposed credentials span a broad range of internal services, including database accounts, licensing, replication services, and third-party integrations, meaning successful exploitation of this vulnerability could provide an attacker with unauthorized access to multiple interconnected systems.
critical 9.3
Storage Concentrator (SC & SCVM) is vulnerable to reflected cross-site scripting due to unsanitized content being echoed back in 404 error pages. An attacker can craft a malicious URL that, when visited by an authenticated user, causes arbitrary script content to execute within the victim's browser session in the context of the application. This could be leveraged to steal session cookies, redirect users, or perform unauthorized actions on behalf of the victim.
medium 5.1
PROMOD V is using insecure HTTP communication instead of HTTPS. The vulnerability is due to the lack of HTTPS support from 3rd party Digipede server.
high 7.0
The WebSocket backend uses charging station identifiers to uniquely associate sessions but allows multiple endpoints to connect using the same session identifier. This implementation results in predictable session identifiers. This vulnerability may allow unauthorized users to authenticate as other users or enable a malicious actor to cause a denial-of-service condition by overwhelming the backend with valid session requests.
medium 6.9
Charging station authentication identifiers are publicly accessible via web-based mapping platforms.
medium 6.9
The WebSocket Application Programming Interface lacks restrictions on the number of authentication requests. This absence of rate limiting may allow an attacker to conduct denial-of-service attacks or brute-force attacks to gain unauthorized access.
high 8.7
WebSocket endpoints lack proper authentication mechanisms, enabling attackers to impersonate charging stations. As a result, attackers can exploit this weakness to gain unauthorized access to sensitive data or perform unauthorized actions. Given that no authentication is required, this can lead to privilege escalation and potentially compromise the security of the entire system.
critical 9.3
CWE-78 Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could allow unauthorized execution of commands with elevated privileges, impacting system integrity, confidentiality, and availability when a privileged authenticated user interacts with a vulnerable network-exposed service.
high 8.6
CWE-476 NULL Pointer Dereference vulnerability exists that could cause a denial-of-service condition, rendering the device’s HMI and configuration functionality unavailable when malformed requests are received over exposed network interfaces.
high 8.7
CWE-522 Insufficiently Protected Credentials vulnerability that could cause unauthorized access and exposure of sensitive information when unauthenticated attacker accesses credentials stored within firmware or system files. With this credential an attacker could subsequently compromise the device if they have physical access to the device.
high 8.7
OS command injection in the environment and tunnel configuration functionality in SIMA GmbH Bondix through version 1.25.7.5 on Linux allows an authenticated attacker with configuration write access to execute arbitrary operating-system commands via crafted configuration values passed to server-side scripts.
high 8.6
A critical remote code execution (RCE) vulnerability has been reported in PTC Windchill PDMlink and PTC FlexPLM. The vulnerability may be exploited through the deserialization of untrusted data. * This advisory also applies to all CPS versions * The identified vulnerability also impacts Windchill and FlexPLM releases prior to 11.0 M030
critical 9.3
SimpleHelp versions 5.5.15 and prior and 6.0 pre-release versions contain an authentication bypass vulnerability in the OIDC authentication flow. When OIDC authentication is configured, identity tokens submitted during login are accepted without verifying their cryptographic signature. In a vulnerable configuration, a remote, unauthenticated attacker can submit a forged token containing arbitrary identity claims to obtain a fully authenticated technician session. In some configurations, this may also allow bypass of multi-factor authentication. No user interaction is required.
critical 9.5
In multiple locations, there is a possible way to achieve code execution due to an integer overflow. This could lead to local escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation.
high 8.4
Path traversal vulnerability in Remote Spark (https://www.Remotespark.Com/) SparkView allows reading and writing arbitrary files in all directories as root. This leads to RCE. The affected component is the RDP drive redirection. Depending on implementation, the vulnerability can be exploited by an unauthenticated attacker. This issue affects SparkView: before build 1127.
critical 10.0
A configuration weakness in the device’s remote management service allows an authenticated session to be established over a communication channel intended solely for vehicle-charger signaling. The service is accessible on interfaces exposed through the charging connector, and it accepts a default administrative credential. A malicious device physically connected to the charging interface could leverage this misconfiguration to obtain full administrative access.
high 8.6
Nx Console is the user interface for Nx & Lerna. On 19 May 2026, a malicious version of Nx Console, 18.95.0, was published at 12:30 PM UTC and removed soon after at 12:48 PM UTC, leaving it available for ~18 minutes in Visual Studio Marketplace. For OpenVSX, the problem was detected later, and the compromised version was available from 12:33 UTC to 13:09 UTC (~36 minutes). Version 18.100.0 of Nx Console is not compromised and users may remediate by upgrading to that version.
critical 9.3
A malicious actor with access to the network could exploit an Improper Input Validation vulnerability found in UniFi OS devices to execute a Command Injection.
critical 10.0
A malicious actor with access to the network could exploit a Path Traversal vulnerability found in UniFi OS devices to access files on the underlying system that could be manipulated to access an underlying account.
critical 10.0
A malicious actor with access to the network could exploit an Improper Access Control vulnerability found in UniFi OS devices to make unauthorized changes to the system.
critical 10.0
Improper link resolution before file access ('link following') in Microsoft Defender allows an authorized attacker to elevate privileges locally.
high 7.8
In ScadaBR version 1.2.0, a Use of Hard-Coded Credentials vulnerability could allow an attacker to access the SCADA system as admin.
medium 5.1
In ScadaBR version 1.2.0, a CSRF vulnerability could allow an attacker to trigger any authenticated action through a victim's session by luring any logged-in user to a malicious webpage.
high 8.6
In ScadaBR version 1.2.0, an OS Command Injection vulnerability could allow an attacker to execute commands as root on the SCADA system.
high 8.7
In ScadaBR version 1.2.0, a Missing Authentication for Critical Function vulnerability could allow an unauthenticated attacker to send a HTTP GET requests to the SCADA system and inject arbitrary sensor readings.
high 8.8
A supply chain attack compromised the official installation packages of DAEMON Tools Lite (Windows versions 12.5.0.2421 through 12.5.0.2434), distributed from the legitimate website daemon-tools.cc between approximately April 8, 2026, and May 5, 2026. Attackers gained unauthorized access to the vendor's (AVB Disc Soft) build or distribution infrastructure and trojanized three binaries: DTHelper.exe, DiscSoftBusServiceLite.exe, and DTShellHlp.exe. These files were digitally signed with the legitimate AVB Disc Soft code-signing certificate, allowing the malicious installers to appear trustworthy and bypass signature-based detection.
critical 9.3
May 2026: This security advisory provides the details and fix information for a vulnerability that was discovered and fixed after the was disclosed in February 2026. This new advisory is for a new vulnerability in the control connection handshaking. The section of this advisory includes Show Control Connections guidance to help with system checks. A vulnerability in the peering authentication in Cisco Catalyst SD-WAN Controller, formerly SD-WAN vSmart, Cisco Catalyst SD-WAN Manager, formerly SD-WAN vManage, and Cisco Catalyst SD-WAN Validator, formerly SD-WAN vBond, could allow an unauthenticated, remote attacker to bypass authentication and obtain administrative privileges on an affected system. This vulnerability exists because the peering authentication mechanism in an affected system is not working properly. An attacker could exploit this vulnerability by sending crafted requests to the affected system. A successful exploit could allow the attacker to log in to an affected Cisco Catalyst SD-WAN Controller as an internal, high-privileged, non-root user account. Using this account, the attacker could access NETCONF, which would then allow the attacker to manipulate network configuration for the SD-WAN fabric.
critical 10.0
CWE‑331: Insufficient Entropy vulnerability exists that could lead to unauthorized access when an attacker on the network can exploit weaknesses in session‑management protections.
high 8.7
On 2026-05-11, between approximately 19:20 and 19:26 UTC, 84 malicious versions across 42 @tanstack/* packages were published to the npm registry. The publishes were authenticated via the legitimate GitHub Actions OIDC trusted-publisher binding for TanStack/router, but the publish workflow itself was not modified. The attacker chained three known vulnerability classes — a pull_request_target "Pwn Request" misconfiguration, GitHub Actions cache poisoning across the fork↔base trust boundary, and runtime memory extraction of the OIDC token from the Actions runner process — to publish credential-stealing malware under a trusted identity. Each affected package received exactly two malicious versions, published a few minutes apart.
critical 9.6
OS command injection in Dashboard Server interface in Universal Robots PolyScope versions prior to 5.25.1 allows unauthenticated attacker to craft commands that will execute code on the robot's OS.
critical 9.8
A vulnerability in Cisco ISE and Cisco ISE-PIC could allow an authenticated, remote attacker to execute arbitrary commands on the underlying operating system of an affected device. To exploit this vulnerability, the attacker must have valid administrative credentials. This vulnerability is due to insufficient validation of user-supplied input. An attacker could exploit this vulnerability by sending a crafted HTTP request to an affected device. A successful exploit could allow the attacker to obtain user-level access to the underlying operating system and then elevate privileges to root. In single-node ISE deployments, successful exploitation of this vulnerability could cause the affected ISE node to become unavailable, resulting in a denial of service (DoS) condition. In that condition, endpoints that have not already authenticated would be unable to access the network until the node is restored.
critical 9.9
Improper input validation in Microsoft Office SharePoint allows an unauthorized attacker to perform spoofing over a network.
medium 6.5
A vulnerability has been identified in Industrial Edge Management Pro V1 (All versions >= V1.7.6 < V1.15.17), Industrial Edge Management Pro V2 (All versions >= V2.0.0 < V2.1.1), Industrial Edge Management Virtual (All versions >= V2.2.0 < V2.8.0). Affected management systems do not properly enforce user authentication on remote connections to devices. This could facilitate an unauthenticated remote attacker to circumvent authentication and impersonate a legitimate user. Successful exploitation requires that the attacker has identified the header and port used for remote connections to devices and that the remote connection feature is enabled for the device. Exploitation allows the attacker to tunnel to the device. Security features on this device itself (e.g. app specific authentication) are not affected.
medium 5.1
A low-privileged remote attacker can send Modbus packets to manipulate register values that are inputs to the odorant injection logic such that too much or too little odorant is injected into a gas line.
high 8.6
OpenPLC_V3 REST API endpoint checks for JWT presence but never verifies the caller's role. Any authenticated user with role=user can delete any other user, including administrators, by specifying their user ID or they can create new accounts with role=admin, escalating to full administrator access.
high 8.7
ChurchCRM is an open-source church management system. Prior to 7.1.0, critical pre-authentication remote code execution vulnerability in ChurchCRM's setup wizard allows unauthenticated attackers to inject arbitrary PHP code during the initial installation process, leading to complete server compromise. The "$dbPassword" variable is not sanitized. This vulnerability exists due to an incomplete fix for CVE-2025-62521. This vulnerability is fixed in 7.1.0.
critical 10.0
SandboxJS is a JavaScript sandboxing library. Prior to 0.8.36, SandboxJS blocks direct assignment to global objects (for example Math.random = ...), but this protection can be bypassed through an exposed callable constructor path: this.constructor.call(target, attackerObject). Because this.constructor resolves to the internal SandboxGlobal function and Function.prototype.call is allowed, attacker code can write arbitrary properties into host global objects and persist those mutations across sandbox instances in the same process. This vulnerability is fixed in 0.8.36.
critical 10.0
OpenPrinting CUPS is an open source printing system for Linux and other Unix-like operating systems. In versions 2.4.16 and prior, CUPS daemon (cupsd) contains an authorization bypass vulnerability due to case-insensitive username comparison during authorization checks. The vulnerability allows an unprivileged user to gain unauthorized access to restricted operations by using a user with a username that differs only in case from an authorized user. At time of publication, there are no publicly available patches.
medium 4.8
An SSH misconfigurations exists in Tenable OT that led to the potential exfiltration of socket, port, and service information via the ostunnel user and GatewayPorts. This could be used to potentially glean information about the underlying system and give an attacker information that could be used to attempt to compromise the host.
low 1.9