ICS vulnerabilities
Showing 201 - 250 of 272 CVEs
- CVE-2024-22024 Published Feb 13, 2024
An XML external entity or XXE vulnerability in the SAML component of Ivanti Connect Secure (9.x, 22.x), Ivanti Policy Secure (9.x, 22.x) and ZTA gateways which allows an attacker to access certain restricted resources without authentication.
- CVE-2024-22016 Published Feb 2, 2024
In Rapid Software LLC's Rapid SCADA versions prior to Version 5.8.4, an authorized user can write directly to the Scada directory. This may allow privilege escalation.
- CVE-2024-21866 Published Feb 2, 2024
In Rapid Software LLC's Rapid SCADA versions prior to Version 5.8.4, the affected product responds back with an error message containing sensitive data if it receives a specific malformed request.
- CVE-2024-21852 Published Feb 1, 2024
In Rapid Software LLC's Rapid SCADA versions prior to Version 5.8.4, an attacker can supply a malicious configuration file by utilizing a Zip Slip vulnerability in the unpacking routine to achieve remote code execution.
- CVE-2024-21893 Published Jan 31, 2024
A server-side request forgery vulnerability in the SAML component of Ivanti Connect Secure (9.x, 22.x) and Ivanti Policy Secure (9.x, 22.x) and Ivanti Neurons for ZTA allows an attacker to access certain restricted resources without authentication.
- CVE-2024-21888 Published Jan 31, 2024
A privilege escalation vulnerability in web component of Ivanti Connect Secure (9.x, 22.x) and Ivanti Policy Secure (9.x, 22.x) allows a user to elevate privileges to that of an administrator.
- CVE-2023-33472 Published Jan 13, 2024
An issue was discovered in Scada-LTS v2.7.5.2 build 4551883606 and before, allows remote attackers with low-level authentication to escalate privileges, execute arbitrary code, and obtain sensitive information via Event Handlers function.
- CVE-2024-21887 Published Jan 12, 2024
A command injection vulnerability in web components of Ivanti Connect Secure (9.x, 22.x) and Ivanti Policy Secure (9.x, 22.x) allows an authenticated administrator to send specially crafted requests and execute arbitrary commands on the appliance.
- CVE-2023-46805 Published Jan 12, 2024
An authentication bypass vulnerability in the web component of Ivanti ICS 9.x, 22.x and Ivanti Policy Secure allows a remote attacker to access restricted resources by bypassing control checks.
- CVE-2023-44373 Published Nov 14, 2023
Affected devices do not properly sanitize an input field. This could allow an authenticated remote attacker with administrative privileges to inject code or spawn a system root shell. Follow-up of CVE-2022-36323.
- CVE-2023-47611 Published Nov 10, 2023
A CWE-269: Improper Privilege Management vulnerability exists in Telit Cinterion BGS5, Telit Cinterion EHS5/6/8, Telit Cinterion PDS5/6/8, Telit Cinterion ELS61/81, Telit Cinterion PLS62 that could allow a local, low privileged attacker to elevate privileges to "manufacturer" level on the targeted system.
- CVE-2023-47614 Published Nov 10, 2023
A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists in Telit Cinterion BGS5, Telit Cinterion EHS5/6/8, Telit Cinterion PDS5/6/8, Telit Cinterion ELS61/81, Telit Cinterion PLS62 that could allow a local, low privileged attacker to disclose hidden virtual paths and file names on the targeted system.
- CVE-2023-47610 Published Nov 9, 2023
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists in Telit Cinterion EHS5/6/8 that could allow a remote unauthenticated attacker to execute arbitrary code on the targeted system by sending a specially crafted SMS message.
- CVE-2023-47616 Published Nov 9, 2023
A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists in Telit Cinterion BGS5, Telit Cinterion EHS5/6/8, Telit Cinterion PDS5/6/8, Telit Cinterion ELS61/81, Telit Cinterion PLS62 that could allow an attacker with physical access to the target system to get access to a sensitive data on the targeted system.
- CVE-2023-47615 Published Nov 9, 2023
A CWE-526: Exposure of Sensitive Information Through Environmental Variables vulnerability exists in Telit Cinterion BGS5, Telit Cinterion EHS5/6/8, Telit Cinterion PDS5/6/8, Telit Cinterion ELS61/81, Telit Cinterion PLS62 that could allow a local, low privileged attacker to get access to a sensitive data on the targeted system.
- CVE-2023-47612 Published Nov 9, 2023
A CWE-552: Files or Directories Accessible to External Parties vulnerability exists in Telit Cinterion BGS5, Telit Cinterion EHS5/6/8, Telit Cinterion PDS5/6/8, Telit Cinterion ELS61/81, Telit Cinterion PLS62 that could allow an attacker with physical access to the target system to obtain a read/write access to any files and directories on the targeted system, including hidden files and directories.
- CVE-2023-47613 Published Nov 9, 2023
A CWE-23: Relative Path Traversal vulnerability exists in Telit Cinterion BGS5, Telit Cinterion EHS5/6/8, Telit Cinterion PDS5/6/8, Telit Cinterion ELS61/81, Telit Cinterion PLS62 that could allow a local, low privileged attacker to escape from virtual directories and get read/write access to protected files on the targeted system.
- CVE-2023-45727 Published Oct 18, 2023
Proself Enterprise/Standard Edition Ver5.62 and earlier, Proself Gateway Edition Ver1.65 and earlier, and Proself Mail Sanitize Edition Ver1.08 and earlier allow a remote unauthenticated attacker to conduct XML External Entity (XXE) attacks. By processing a specially crafted request containing malformed XML data, arbitrary files on the server containing account information may be read by the attacker.
- CVE-2023-45852 Published Oct 14, 2023
In Vitogate 300 2.1.3.0, /cgi-bin/vitogate.cgi allows an unauthenticated attacker to bypass authentication and execute arbitrary commands via shell metacharacters in the ipaddr params JSON data for the put method.
- CVE-2023-4485 Published Sep 6, 2023
ARDEREG Sistema SCADA Central versions 2.203 and prior login page are vulnerable to an unauthenticated blind SQL injection attack. An attacker could manipulate the application's SQL query logic to extract sensitive information or perform unauthorized actions within the database. In this case, the vulnerability could allow an attacker to execute arbitrary SQL queries through the login page, potentially leading to unauthorized access, data leakage, or even disruption of critical industrial processes.
- CVE-2023-1437 Published Aug 2, 2023
All versions prior to 9.1.4 of Advantech WebAccess/SCADA are vulnerable to use of untrusted pointers. The RPC arguments the client sent could contain raw memory pointers for the server to use as-is. This could allow an attacker to gain access to the remote file system and the ability to execute commands and overwrite files.
- CVE-2023-3256 Published Jun 22, 2023
Advantech R-SeeNet versions 2.4.22 allows low-level users to access and load the content of local files.
- CVE-2023-2611 Published Jun 22, 2023
Advantech R-SeeNet versions 2.4.22 is installed with a hidden root-level user that is not available in the users list. This hidden user has a password that cannot be changed by users.
- CVE-2023-2866 Published Jun 7, 2023
If an attacker can trick an authenticated user into loading a maliciously crafted .zip file onto Advantech WebAccess version 8.4.5, a web shell could be used to give the attacker full control of the SCADA server.
- CVE-2023-29169 Published Apr 27, 2023
mySCADA myPRO versions 8.26.0 and prior has parameters which an authenticated user could exploit to inject arbitrary operating system commands.
- CVE-2023-29150 Published Apr 27, 2023
mySCADA myPRO versions 8.26.0 and prior has parameters which an authenticated user could exploit to inject arbitrary operating system commands.
- CVE-2023-28716 Published Apr 27, 2023
mySCADA myPRO versions 8.26.0 and prior has parameters which an authenticated user could exploit to inject arbitrary operating system commands.
- CVE-2023-1256 Published Mar 16, 2023
The listed versions of AVEVA Plant SCADA and AVEVA Telemetry Server are vulnerable to an improper authorization exploit which could allow an unauthenticated user to remotely read data, cause denial of service, and tamper with alarm states.
- CVE-2023-22424 Published Mar 6, 2023
Use-after-free vulnerability exists in Kostac PLC Programming Software (Former name: Koyo PLC Programming Software) Version 1.6.9.0 and earlier. With the abnormal value given as the maximum number of columns for the PLC program, the process accesses the freed memory. As a result, opening a specially crafted project file may lead to information disclosure and/or arbitrary code execution.
- CVE-2023-22421 Published Mar 6, 2023
Out-of-bounds read vulnerability exists in Kostac PLC Programming Software (Former name: Koyo PLC Programming Software) Version 1.6.9.0 and earlier. The insufficient buffer size for the PLC program instructions leads to out-of-bounds read. As a result, opening a specially crafted project file may lead to information disclosure and/or arbitrary code execution.
- CVE-2023-22419 Published Mar 6, 2023
Out-of-bounds read vulnerability exists in Kostac PLC Programming Software (Former name: Koyo PLC Programming Software) Version 1.6.9.0 and earlier. When processing a comment block in stage information, the end of data cannot be verified and out-of-bounds read occurs. As a result, opening a specially crafted project file may lead to information disclosure and/or arbitrary code execution.
- CVE-2023-0457 Published Mar 3, 2023
Plaintext Storage of a Password vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F Series, MELSEC iQ-R Series, MELSEC-Q Series and MELSEC-L Series allows a remote unauthenticated attacker to disclose plaintext credentials stored in project files and login into FTP server or Web server.
- CVE-2023-0451 Published Jan 26, 2023
Econolite EOS versions prior to 3.2.23 lack a password requirement for gaining “READONLY” access to log files and certain database and configuration files. One such file contains tables with MD5 hashes and usernames for all defined users in the control software, including administrators and technicians.
- CVE-2022-3270 Published Dec 1, 2022
In multiple products by Festo a remote unauthenticated attacker could use functions of an undocumented protocol which could lead to a complete loss of confidentiality, integrity and availability.
- CVE-2022-40799 Published Nov 29, 2022
Data Integrity Failure in 'Backup Config' in D-Link DNR-322L <= 2.60B15 allows an authenticated attacker to execute OS level commands on the device.
- CVE-2022-20775 Published Sep 30, 2022
A vulnerability in the CLI of Cisco SD-WAN Software could allow an authenticated, local attacker to gain elevated privileges. This vulnerability is due to improper access controls on commands within the application CLI. An attacker could exploit this vulnerability by running a maliciously crafted command on the application CLI. A successful exploit could allow the attacker to execute arbitrary commands as the root user. Cisco has released software updates that address this vulnerability. There are no workarounds that address this vulnerability. https://sec.cloudapps.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-sd-wan-priv-E6e8tEdF
- CVE-2022-37300 Published Sep 12, 2022
A CWE-640: Weak Password Recovery Mechanism for Forgotten Password vulnerability exists that could cause unauthorized access in read and write mode to the controller when communicating over Modbus. Affected Products: EcoStruxure Control Expert Including all Unity Pro versions (former name of EcoStruxure Control Expert) (V15.0 SP1 and prior), EcoStruxure Process Expert, Including all versions of EcoStruxure Hybrid DCS (former name of EcoStruxure Process Expert) (V2021 and prior), Modicon M340 CPU (part numbers BMXP34*) (V3.40 and prior), Modicon M580 CPU (part numbers BMEP* and BMEH*) (V3.20 and prior).
- CVE-2022-1161 Published Apr 11, 2022
An attacker with the ability to modify a user program may change user program code on some ControlLogix, CompactLogix, and GuardLogix Control systems. Studio 5000 Logix Designer writes user-readable program code to a separate location than the executed compiled code, allowing an attacker to change one and not the other.
- CVE-2020-25184 Published Mar 18, 2022
Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x stores the password in plaintext in a file that is in the same directory as the executable file. ISaGRAF Runtime reads the file and saves the data in a variable without any additional modification. A local, unauthenticated attacker could compromise the user passwords, resulting in information disclosure.
- CVE-2020-25182 Published Mar 18, 2022
Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x searches for and loads DLLs as dynamic libraries. Uncontrolled loading of dynamic libraries could allow a local, unauthenticated attacker to execute arbitrary code. This vulnerability only affects ISaGRAF Runtime when running on Microsoft Windows systems.
- CVE-2020-25180 Published Mar 18, 2022
Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x includes the functionality of setting a password that is required to execute privileged commands. The password value passed to ISaGRAF Runtime is the result of encryption performed with a fixed key value using the tiny encryption algorithm (TEA) on an entered or saved password. A remote, unauthenticated attacker could pass their own encrypted password to the ISaGRAF 5 Runtime, which may result in information disclosure on the device.
- CVE-2020-16232 Published Mar 18, 2022
In Yokogawa WideField3 R1.01 - R4.03, a buffer overflow could be caused when a user loads a maliciously crafted project file.
- CVE-2022-0492 Published Mar 3, 2022
A vulnerability was found in the Linux kernel’s cgroup_release_agent_write in the kernel/cgroup/cgroup-v1.c function. This flaw, under certain circumstances, allows the use of the cgroups v1 release_agent feature to escalate privileges and bypass the namespace isolation unexpectedly.
- CVE-2022-25359 Published Feb 26, 2022
On ICL ScadaFlex II SCADA Controller SC-1 and SC-2 1.03.07 devices, unauthenticated remote attackers can overwrite, delete, or create files.
- CVE-2022-23921 Published Feb 25, 2022
Exploitation of this vulnerability may result in local privilege escalation and code execution. GE maintains exploitation of this vulnerability is only possible if the attacker has login access to a machine actively running CIMPLICITY, the CIMPLICITY server is not already running a project, and the server is licensed for multiple projects.
- CVE-2022-21798 Published Feb 25, 2022
The affected product is vulnerable due to cleartext transmission of credentials seen in the CIMPLICITY network, which can be easily spoofed and used to log in to make operational changes to the system.
- CVE-2022-24316 Published Feb 9, 2022
A CWE-665: Improper Initialization vulnerability exists that could cause information exposure when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)
- CVE-2022-23130 Published Jan 21, 2022
Buffer Over-read vulnerability in Mitsubishi Electric MC Works64 versions 4.00A to 4.04E, Mitsubishi Electric GENESIS64 versions 10.97 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 and prior, Mitsubishi Electric ICONICS Suite versions 10.97 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 and prior, Mitsubishi Electric GENESIS32 versions 9.7 and prior, and Mitsubishi Electric Iconics Digital Solutions GENESIS32 versions 9.7 and prior allows an attacker to cause a DoS condition in the database server by getting a legitimate user to import a configuration file containing specially crafted stored procedures into GENESIS64, ICONICS Suite, MC Works64, or GENESIS32 and execute commands against the database from GENESIS64, ICONICS Suite, MC Works64, or GENESIS32.
- CVE-2022-23129 Published Jan 21, 2022
Plaintext Storage of a Password vulnerability in Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior and ICONICS GENESIS64 versions 10.90 to 10.97 allows a local authenticated attacker to gain authentication information and to access the database illegally. This is because when configuration information of GridWorX, a database linkage function of GENESIS64 and MC Works64, is exported to a CSV file, the authentication information is saved in plaintext, and an attacker who can access this CSV file can gain the authentication information.
- CVE-2022-23128 Published Jan 21, 2022
Incomplete List of Disallowed Inputs vulnerability in Mitsubishi Electric MC Works64 versions 4.00A (10.95.201.23) to 4.04E (10.95.210.01), ICONICS GENESIS64 versions 10.95.3 to 10.97, ICONICS Hyper Historian versions 10.95.3 to 10.97, ICONICS AnalytiX versions 10.95.3 to 10.97 and ICONICS MobileHMI versions 10.95.3 to 10.97 allows a remote unauthenticated attacker to bypass the authentication of MC Works64, GENESIS64, Hyper Historian, AnalytiX and MobileHMI, and gain unauthorized access to the products, by sending specially crafted WebSocket packets to FrameWorX server, one of the functions of the products.
An XML external entity or XXE vulnerability in the SAML component of Ivanti Connect Secure (9.x, 22.x), Ivanti Policy Secure (9.x, 22.x) and ZTA gateways which allows an attacker to access certain restricted resources without authentication.
high 8.3
In Rapid Software LLC's Rapid SCADA versions prior to Version 5.8.4, an authorized user can write directly to the Scada directory. This may allow privilege escalation.
high 7.8
In Rapid Software LLC's Rapid SCADA versions prior to Version 5.8.4, the affected product responds back with an error message containing sensitive data if it receives a specific malformed request.
medium 5.3
In Rapid Software LLC's Rapid SCADA versions prior to Version 5.8.4, an attacker can supply a malicious configuration file by utilizing a Zip Slip vulnerability in the unpacking routine to achieve remote code execution.
high 8.8
A server-side request forgery vulnerability in the SAML component of Ivanti Connect Secure (9.x, 22.x) and Ivanti Policy Secure (9.x, 22.x) and Ivanti Neurons for ZTA allows an attacker to access certain restricted resources without authentication.
high 8.2
A privilege escalation vulnerability in web component of Ivanti Connect Secure (9.x, 22.x) and Ivanti Policy Secure (9.x, 22.x) allows a user to elevate privileges to that of an administrator.
high 8.8
An issue was discovered in Scada-LTS v2.7.5.2 build 4551883606 and before, allows remote attackers with low-level authentication to escalate privileges, execute arbitrary code, and obtain sensitive information via Event Handlers function.
high 8.8
A command injection vulnerability in web components of Ivanti Connect Secure (9.x, 22.x) and Ivanti Policy Secure (9.x, 22.x) allows an authenticated administrator to send specially crafted requests and execute arbitrary commands on the appliance.
critical 9.1
An authentication bypass vulnerability in the web component of Ivanti ICS 9.x, 22.x and Ivanti Policy Secure allows a remote attacker to access restricted resources by bypassing control checks.
high 8.2
Affected devices do not properly sanitize an input field. This could allow an authenticated remote attacker with administrative privileges to inject code or spawn a system root shell. Follow-up of CVE-2022-36323.
critical 9.4
A CWE-269: Improper Privilege Management vulnerability exists in Telit Cinterion BGS5, Telit Cinterion EHS5/6/8, Telit Cinterion PDS5/6/8, Telit Cinterion ELS61/81, Telit Cinterion PLS62 that could allow a local, low privileged attacker to elevate privileges to "manufacturer" level on the targeted system.
high 7.8
A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists in Telit Cinterion BGS5, Telit Cinterion EHS5/6/8, Telit Cinterion PDS5/6/8, Telit Cinterion ELS61/81, Telit Cinterion PLS62 that could allow a local, low privileged attacker to disclose hidden virtual paths and file names on the targeted system.
low 3.3
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists in Telit Cinterion EHS5/6/8 that could allow a remote unauthenticated attacker to execute arbitrary code on the targeted system by sending a specially crafted SMS message.
high 8.1
A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists in Telit Cinterion BGS5, Telit Cinterion EHS5/6/8, Telit Cinterion PDS5/6/8, Telit Cinterion ELS61/81, Telit Cinterion PLS62 that could allow an attacker with physical access to the target system to get access to a sensitive data on the targeted system.
low 2.4
A CWE-526: Exposure of Sensitive Information Through Environmental Variables vulnerability exists in Telit Cinterion BGS5, Telit Cinterion EHS5/6/8, Telit Cinterion PDS5/6/8, Telit Cinterion ELS61/81, Telit Cinterion PLS62 that could allow a local, low privileged attacker to get access to a sensitive data on the targeted system.
low 3.3
A CWE-552: Files or Directories Accessible to External Parties vulnerability exists in Telit Cinterion BGS5, Telit Cinterion EHS5/6/8, Telit Cinterion PDS5/6/8, Telit Cinterion ELS61/81, Telit Cinterion PLS62 that could allow an attacker with physical access to the target system to obtain a read/write access to any files and directories on the targeted system, including hidden files and directories.
medium 6.8
A CWE-23: Relative Path Traversal vulnerability exists in Telit Cinterion BGS5, Telit Cinterion EHS5/6/8, Telit Cinterion PDS5/6/8, Telit Cinterion ELS61/81, Telit Cinterion PLS62 that could allow a local, low privileged attacker to escape from virtual directories and get read/write access to protected files on the targeted system.
medium 4.4
Proself Enterprise/Standard Edition Ver5.62 and earlier, Proself Gateway Edition Ver1.65 and earlier, and Proself Mail Sanitize Edition Ver1.08 and earlier allow a remote unauthenticated attacker to conduct XML External Entity (XXE) attacks. By processing a specially crafted request containing malformed XML data, arbitrary files on the server containing account information may be read by the attacker.
high 7.5
In Vitogate 300 2.1.3.0, /cgi-bin/vitogate.cgi allows an unauthenticated attacker to bypass authentication and execute arbitrary commands via shell metacharacters in the ipaddr params JSON data for the put method.
critical 9.8
ARDEREG Sistema SCADA Central versions 2.203 and prior login page are vulnerable to an unauthenticated blind SQL injection attack. An attacker could manipulate the application's SQL query logic to extract sensitive information or perform unauthorized actions within the database. In this case, the vulnerability could allow an attacker to execute arbitrary SQL queries through the login page, potentially leading to unauthorized access, data leakage, or even disruption of critical industrial processes.
critical 9.8
All versions prior to 9.1.4 of Advantech WebAccess/SCADA are vulnerable to use of untrusted pointers. The RPC arguments the client sent could contain raw memory pointers for the server to use as-is. This could allow an attacker to gain access to the remote file system and the ability to execute commands and overwrite files.
critical 9.8
Advantech R-SeeNet versions 2.4.22 allows low-level users to access and load the content of local files.
high 8.8
Advantech R-SeeNet versions 2.4.22 is installed with a hidden root-level user that is not available in the users list. This hidden user has a password that cannot be changed by users.
critical 9.8
If an attacker can trick an authenticated user into loading a maliciously crafted .zip file onto Advantech WebAccess version 8.4.5, a web shell could be used to give the attacker full control of the SCADA server.
high 7.8
mySCADA myPRO versions 8.26.0 and prior has parameters which an authenticated user could exploit to inject arbitrary operating system commands.
high 8.8
mySCADA myPRO versions 8.26.0 and prior has parameters which an authenticated user could exploit to inject arbitrary operating system commands.
high 8.8
mySCADA myPRO versions 8.26.0 and prior has parameters which an authenticated user could exploit to inject arbitrary operating system commands.
high 8.8
The listed versions of AVEVA Plant SCADA and AVEVA Telemetry Server are vulnerable to an improper authorization exploit which could allow an unauthenticated user to remotely read data, cause denial of service, and tamper with alarm states.
critical 9.8
Use-after-free vulnerability exists in Kostac PLC Programming Software (Former name: Koyo PLC Programming Software) Version 1.6.9.0 and earlier. With the abnormal value given as the maximum number of columns for the PLC program, the process accesses the freed memory. As a result, opening a specially crafted project file may lead to information disclosure and/or arbitrary code execution.
high 7.8
Out-of-bounds read vulnerability exists in Kostac PLC Programming Software (Former name: Koyo PLC Programming Software) Version 1.6.9.0 and earlier. The insufficient buffer size for the PLC program instructions leads to out-of-bounds read. As a result, opening a specially crafted project file may lead to information disclosure and/or arbitrary code execution.
high 7.8
Out-of-bounds read vulnerability exists in Kostac PLC Programming Software (Former name: Koyo PLC Programming Software) Version 1.6.9.0 and earlier. When processing a comment block in stage information, the end of data cannot be verified and out-of-bounds read occurs. As a result, opening a specially crafted project file may lead to information disclosure and/or arbitrary code execution.
high 7.8
Plaintext Storage of a Password vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F Series, MELSEC iQ-R Series, MELSEC-Q Series and MELSEC-L Series allows a remote unauthenticated attacker to disclose plaintext credentials stored in project files and login into FTP server or Web server.
high 7.5
Econolite EOS versions prior to 3.2.23 lack a password requirement for gaining “READONLY” access to log files and certain database and configuration files. One such file contains tables with MD5 hashes and usernames for all defined users in the control software, including administrators and technicians.
high 7.5
In multiple products by Festo a remote unauthenticated attacker could use functions of an undocumented protocol which could lead to a complete loss of confidentiality, integrity and availability.
critical 9.8
Data Integrity Failure in 'Backup Config' in D-Link DNR-322L <= 2.60B15 allows an authenticated attacker to execute OS level commands on the device.
high 8.8
A vulnerability in the CLI of Cisco SD-WAN Software could allow an authenticated, local attacker to gain elevated privileges. This vulnerability is due to improper access controls on commands within the application CLI. An attacker could exploit this vulnerability by running a maliciously crafted command on the application CLI. A successful exploit could allow the attacker to execute arbitrary commands as the root user. Cisco has released software updates that address this vulnerability. There are no workarounds that address this vulnerability. https://sec.cloudapps.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-sd-wan-priv-E6e8tEdF
high 7.8
A CWE-640: Weak Password Recovery Mechanism for Forgotten Password vulnerability exists that could cause unauthorized access in read and write mode to the controller when communicating over Modbus. Affected Products: EcoStruxure Control Expert Including all Unity Pro versions (former name of EcoStruxure Control Expert) (V15.0 SP1 and prior), EcoStruxure Process Expert, Including all versions of EcoStruxure Hybrid DCS (former name of EcoStruxure Process Expert) (V2021 and prior), Modicon M340 CPU (part numbers BMXP34*) (V3.40 and prior), Modicon M580 CPU (part numbers BMEP* and BMEH*) (V3.20 and prior).
critical 9.8
An attacker with the ability to modify a user program may change user program code on some ControlLogix, CompactLogix, and GuardLogix Control systems. Studio 5000 Logix Designer writes user-readable program code to a separate location than the executed compiled code, allowing an attacker to change one and not the other.
critical 10.0
Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x stores the password in plaintext in a file that is in the same directory as the executable file. ISaGRAF Runtime reads the file and saves the data in a variable without any additional modification. A local, unauthenticated attacker could compromise the user passwords, resulting in information disclosure.
high 7.8
Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x searches for and loads DLLs as dynamic libraries. Uncontrolled loading of dynamic libraries could allow a local, unauthenticated attacker to execute arbitrary code. This vulnerability only affects ISaGRAF Runtime when running on Microsoft Windows systems.
medium 6.7
Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x includes the functionality of setting a password that is required to execute privileged commands. The password value passed to ISaGRAF Runtime is the result of encryption performed with a fixed key value using the tiny encryption algorithm (TEA) on an entered or saved password. A remote, unauthenticated attacker could pass their own encrypted password to the ISaGRAF 5 Runtime, which may result in information disclosure on the device.
medium 5.3
In Yokogawa WideField3 R1.01 - R4.03, a buffer overflow could be caused when a user loads a maliciously crafted project file.
low 2.8
A vulnerability was found in the Linux kernel’s cgroup_release_agent_write in the kernel/cgroup/cgroup-v1.c function. This flaw, under certain circumstances, allows the use of the cgroups v1 release_agent feature to escalate privileges and bypass the namespace isolation unexpectedly.
high 7.8
On ICL ScadaFlex II SCADA Controller SC-1 and SC-2 1.03.07 devices, unauthenticated remote attackers can overwrite, delete, or create files.
critical 9.1
Exploitation of this vulnerability may result in local privilege escalation and code execution. GE maintains exploitation of this vulnerability is only possible if the attacker has login access to a machine actively running CIMPLICITY, the CIMPLICITY server is not already running a project, and the server is licensed for multiple projects.
high 7.5
The affected product is vulnerable due to cleartext transmission of credentials seen in the CIMPLICITY network, which can be easily spoofed and used to log in to make operational changes to the system.
high 7.5
A CWE-665: Improper Initialization vulnerability exists that could cause information exposure when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)
high 7.5
Buffer Over-read vulnerability in Mitsubishi Electric MC Works64 versions 4.00A to 4.04E, Mitsubishi Electric GENESIS64 versions 10.97 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 and prior, Mitsubishi Electric ICONICS Suite versions 10.97 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 and prior, Mitsubishi Electric GENESIS32 versions 9.7 and prior, and Mitsubishi Electric Iconics Digital Solutions GENESIS32 versions 9.7 and prior allows an attacker to cause a DoS condition in the database server by getting a legitimate user to import a configuration file containing specially crafted stored procedures into GENESIS64, ICONICS Suite, MC Works64, or GENESIS32 and execute commands against the database from GENESIS64, ICONICS Suite, MC Works64, or GENESIS32.
medium 5.9
Plaintext Storage of a Password vulnerability in Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior and ICONICS GENESIS64 versions 10.90 to 10.97 allows a local authenticated attacker to gain authentication information and to access the database illegally. This is because when configuration information of GridWorX, a database linkage function of GENESIS64 and MC Works64, is exported to a CSV file, the authentication information is saved in plaintext, and an attacker who can access this CSV file can gain the authentication information.
medium 5.5
Incomplete List of Disallowed Inputs vulnerability in Mitsubishi Electric MC Works64 versions 4.00A (10.95.201.23) to 4.04E (10.95.210.01), ICONICS GENESIS64 versions 10.95.3 to 10.97, ICONICS Hyper Historian versions 10.95.3 to 10.97, ICONICS AnalytiX versions 10.95.3 to 10.97 and ICONICS MobileHMI versions 10.95.3 to 10.97 allows a remote unauthenticated attacker to bypass the authentication of MC Works64, GENESIS64, Hyper Historian, AnalytiX and MobileHMI, and gain unauthorized access to the products, by sending specially crafted WebSocket packets to FrameWorX server, one of the functions of the products.
critical 9.8